2. Install the Urinal
For Retrofit Installations
NOTE: The lip height of the urinal will be 6" (15.2 cm) above the
center of the outlet location. If this lip height is not acceptable,
relocate the outlet to achieve an acceptable lip height. The existing
collar may be used with the bracket.
For All Installations
Reference the installation template and position each wall hanger
at the vertical dimension above the outlet hole shown on the
template. To allow for vertical adjustment, place initial screws
through the center of the slots on the wall hangers.
Apply thread sealant tape to the threads on the waste pipe, then
and install the collar to the waste pipe.
Center the bracket on top of the collar. Secure two screws through
the slots on the bracket and into the threaded holes on the collar.
With the beveled surface of the gasket facing away from the
collar, seat the gasket firmly against the collar.
CAUTION: Risk of personal injury or product damage. Handle
with care. Vitreous china can break or chip if the product is
handled carelessly.
Carefully position the urinal on the wall hangers.
Verify the urinal is properly positioned, then remove the urinal
from the wall.