INTRODUCTION


Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www.P65warnings.ca.gov.

DISCLAIMERS

All information, illustrations, and specifications in this manual were in effect at the time of publishing. The illustrations used in this manual are intended as representative reference views only. We reserve the right to make any specification or design change without notice.

ALL RIGHTS RESERVED

All rights reserved. No reproduction allowed in any form without written permission from Westinghouse Outdoor Power Equipment, LLC.



Read this manual before using or performing maintenance on this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS

SPECIFICATIONS

Running Watts: 5300
Peak Watts: 6600
Rated Voltage: 120V/240V
Rated frequency: 60 Hz @ 3600 RPM
Phase: Single phase
Total Harmonic Distortion: ≤ 23%
Engine Displacement: 274 cc
Starting Type: Recoil
Fuel Capacity: 4.7 Gallons (18 Liters)
Fuel Type: Unleaded gasoline 87–93 octane*
Oil Capacity: 0.74 Quart (0.7 Liter)
Oil Type: SAE 10W-30
Spark Plug: 97108 (F7TC)
Spark Plug Gap: 0.024 – 0.032 in. (0.60 – 0.80 mm)
Valve Intake Clearance: 0.0031 – 0.0047 in. (0.08 – 0.12 mm)
Valve Exhaust Clearance: 0.0051 – 0.0067 in. (0.13 – 0.17 mm)
AC Grounding System: Neutral bonded to frame
Voltage Regulator: AVR
Alternator Type: Brushed
Maximum Ambient Temperature: 104°F (40°C)
Certifications:
  • EPA
  • CARB

*Ethanol content of 10% or less. DO NOT use E15 or E85.

UPDATES
Scan the following QR code with your smartphone camera to be directed to the link.

NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). If needed, this product can be operated at temperatures ranging from 5°F (15°C)–122°F (50°C) for short periods. If the product is exposed to temperatures outside of this range during storage, it should be brought back within this range before operation. This product must ALWAYS be operated outdoors in a well-ventilated area and far away from doors, windows, and other vents. Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F (6°C) above 60°F (16°C) ambient temperature.

PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to register your Westinghouse generator.
You can register by:

  • Completing and mailing the product registration card included in the carton.
  • Registering your product online at: https://westinghouseoutdoorpower.com/pages/warranty-registration
  • Scan the following QR code with your smartphone camera to be directed to the mobile registration link.
  • Sending the following product information to: Westinghouse Outdoor Power
    Warranty registration
    777 Manor Park Drive Columbus, OH 43228
    For Your Records
    Date of Purchase:
    Model Number:
    Serial Number:
    Place of Purchase:


Keep your purchase receipt for trouble-free warranty coverage.

SAFETY

SAFETY DEFINITIONS

The words DANGER, WARNING, CAUTION, and NOTICE are used throughout this manual to highlight important information. Make sure that the meanings of this safety information is known to all who operate, perform maintenance on, or are near the generator.
warningThis safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Read and abide by the message that follows the safety alerts symbol.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal property, and/or the environment, or cause the equipment to operate improperly.

Note: Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended.

SAFETY SYMBOLS

Follow all safety information contained in this manual and on the generator.

Symbol Description
warning Safety Alert Symbol
Electrocution Hazard
Asphyxiation Hazard
Burn Hazard. DO NOT touch hot surfaces.
shock hazard Electrical Shock Hazard
Fire Hazard
Maintain Safe Distance
Lifting Hazard
Read Manufacturer's Instructions
DO NOT Operate in Wet Conditions
Ground. Consult with electrician to determine grounding requirements before operation.


Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

SAFETY INSTRUCTIONS

CORRECT USAGE
Example location to reduce risk of carbon monoxide poisoning ONLY use outside and downwind, far away from windows, doors and vents. Direct exhaust away from occupied spaces
SAFETY INSTRUCTIONS
INCORRECT USAGE
Do not operate in any of the following locations:
Near any door, window, or vent

  • Garage
  • Basement
  • Crawl Space
  • Living Area
  • Attic
  • Entry Way
  • Porch
  • Mudroom

NOTICE
Install battery-powered carbon monoxide detectors or plug-in carbon monoxide detectors with battery back-up in living areas.

Fire and electrocution hazard. DO NOT connect to a building's electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.

Electrocution hazard. NEVER use the generator in a location that is wet or damp. NEVER expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.

GENERAL SAFETY PRECAUTIONS

  • NEVER use the generator to power medical support equipment.
  • DO NOT operate the generator when you are tired or under the influence of drugs, alcohol, or medication.
  • DO NOT use generator with electrical cords which are worn, frayed, bare, or otherwise damaged.
  • All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be double-insulated.
  • When this generator is used to supply a building wiring system the generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70, National Electrical Code.
  • If you begin to feel sick, dizzy, or weak while using the generator, move to fresh air IMMEDIATELY. See a doctor, as you can have carbon monoxide poisoning.
  • Only use OUTSIDE and far away from windows, doors, and vents as recommended by the US Department of Health and Human Services Centers for Disease Control and Prevention. Your specific home and/or wind conditions may require additional distance.
  • While operating and storing, keep at least five feet of clearance on all sides of the generator, including overhead. Allow the generator to cool a minimum of 30 minutes before storage. Heat created by the muffler and exhaust gases could be hot enough to cause serious burns and/or ignite combustible objects.
  • DO NOT touch the muffler or engine. They are very HOT and will cause severe burns. DO NOT put body parts or any flammable or combustible materials in the direct path of the exhaust.
  • ALWAYS remove any tools or other service equipment used during maintenance away from the generator before operating.
  • Avoid skin contact with engine oil or gasoline. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
  • A transfer switch must be installed by a licensed electrician approved by the authority having jurisdiction. The installation must comply with all applicable laws and electrical codes.

FUEL SAFETY

  • Store fuel in a container approved for gasoline.
  • DO NOT smoke when filling the generator with gasoline.
  • DO NOT allow the generator's gas tank to overflow when filling.
  • Shut down the engine and allow it to cool for two minutes before adding gasoline or oil to the generator.
  • NEVER remove the fuel cap when the generator is running. Shut off the engine and allow the unit to cool at least two minutes. Remove the fuel cap slowly to release pressure, keep fuel from escaping around the cap, and to avoid the heat from the muffler igniting fuel vapors. Tighten the fuel cap securely after refueling.
  • Wipe spilled fuel from the unit.
  • NEVER attempt to burn off spilled fuel.
  • NEVER overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.
  • Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of rag properly. Allow area of spilled fuel to dry before operating the generator.
  • Wear eye protection while refueling.
  • NEVER use gasoline as a cleaning agent.
  • Store any containers containing gasoline or in a well- ventilated area, away from any combustibles or source of ignition.

GASOLINE AND GASOLINE VAPOR (GAS)


Fire and explosion hazard. Gasoline and is highly explosive and flammable and can cause severe burns or death.

  • In case of a gas fire, DO NOT attempt to extinguish the flame if the fuel tank valve is in the ON position. Introducing an extinguisher to a generator with an open fuel valve could create an explosion hazard.
  • Gas has a distinctive odor, this will help detect potential leaks quickly.
  • Gas vapors can cause a fire if ignited.
  • Gasoline is a skin irritant and needs to be cleaned up immediately if it comes in contact with the skin.
  • Flammable gas under pressure can cause a fire or explosion if ignited.

WHEN STARTING THE GENERATOR:

  • Make sure that the fuel cap, air filter, spark plug, fuel lines, and exhaust system are properly in place.
  • If you spill any gasoline on the tank, allow it to fully evaporate before operating.
  • Make sure the generator is on a flat surface before operating.

WHEN TRANSPORTING OR SERVICING THE GENERATOR:

  • Disconnect the spark boot to prevent accidental starting.

WHEN STORING THE GENERATOR:

  • Store away from sparks, open flames, pilot lights, heat, and other sources of ignition.

SAFETY LABELS

SAFETY LABELS OVERVIEW - PART 1
SAFETY LABELS OVERVIEW - PART 2

COMPONENTS

CONTROL PANEL COMPONENTS

CONTROL PANEL COMPONENTS

  1. Run/Stop Switch: Push to Run position to start or Stop position to shut the generator off.
  2. Data Center: Toggle to show voltage, frequency, total hour meter, and run/maintenance timer.
  3. Voltage Selector Switch: Select 120 Volts or 240 Volts. Shut the generator OFF before switching voltages.
  4. 120/240 Volt AC, 30 Amp NEMA L14-30R Twist Lock Receptacle: Receptacle can supply either 120V or 240V output.
  5. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle: Receptacle can supply a maximum of 30 Amps.
  6. 120 Volt AC, 20 Amp Duplex NEMA 5-20R Receptacles: Receptacles can supply a maximum of 20 Amps.
  7. 20 Amp AC Circuit Breaker: Circuit breaker limits the current that can be delivered through the NEMA 5-20R receptacles to 20 Amps.
  8. 30 Amp AC Circuit Breaker: Circuit breaker limits the current that can be delivered through the TT- 30R receptacle to 30 Amps.
  9. 22-Amp Circuit Breakers: Each circuit breaker limits the current that can be delivered through each 120 Volt leg on L14-30R to 22 Amps.
  10. Ground Terminal: The ground terminal is used to externally ground the generator.

DATA CENTER
Voltage:

Displays current voltage output.
Frequency (Hz):

Displays power output frequency in Hertz.
Lifetime Hours:

Displays the lifetime run hours.
Run Time/Maintenance:

Displays current run time. Resets to zero when shut down. Maintenance reminder displayed

GENERATOR COMPONENTS

GENERATOR COMPONENTS

ASSEMBLY

CARTON CONTENTS


Weight hazard. ALWAYS have assistance when lifting the generator.

  1. Carefully open the carton.
  2. Remove and save the carton contents.
  3. Remove and discard the packing tray.
  4. Unfold the top of the plastic bag enclosing the generator.
  5. Carefully cut the vertical corners of the carton to access the generator.
  6. Recycle or dispose of the packaging materials properly.

CARTON CONTENTS

  • User manual
  • Quick Start Guide
  • Bottle of SAE 10W-30 oil
  • Spark plug socket wrench
  • Wrench
  • Oil Funnel
  • Wheel and mounting foot components
Item Quantity
  • Mounting foot
2
  • Flange bolt, M8
4
  • Wheel
2
  • Axle pin
2
  • Washer
2
  • Cotter pin
2

If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.

INSTALL FEET AND WHEELS

NOTICE
Assembling the generator will require lifting the unit on one side. Install the mounting feet and wheel before adding fuel or oil.

  1. Place generator on a flat surface.
  2. Tip the generator on a piece of cardboard or other soft material to protect the frame paint and prevent the generator from sliding.
  3. With the included wrench, install the mounting feet to the frame as shown.

  1. Install the wheels as shown.
    INSTALL FEET AND WHEELS

Note: The wheels are only intended for hand transport. The wheels are not suitable for towing the generator either on or off-road.

INITIAL OIL FILL FUEL

NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT
OIL. DO NOT attempt to crank or start engine before it has been properly serviced with recommended oil. Failure to add engine oil before starting will result in serious engine damage.

The included, recommended oil type for typical use is 10W-30 engine oil. If running the generator in extreme temperatures, refer to the following chart.
INITIAL OIL FILL FUEL - PART 1

  1. On a level surface, remove the oil dipstick.
    INITIAL OIL FILL FUEL - PART 2
  2. Using the supplied funnel and oil, add oil into oil filler neck.
    Note: As residual oil from the factory may remain in the engine, add the oil incrementally near the end of the bottle to prevent overfilling the engine. See Engine Oil Level Check in the Maintenance section.
  3. Wipe the oil dipstick clean. Replace the oil dipstick and hand-tighten.

FUEL


Fire and explosion hazard. NEVER use a gasoline container, gasoline tank, or any other fuel item that is broken, cut, torn or damaged.

Fire and explosion hazard. DO NOT overfill fuel tank. Fill only to the red fill ring located in the in-tank fuel screen filter. Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard.

Fire and explosion hazard. NEVER refuel the generator while the engine is running. ALWAYS turn the engine off and allow the generator to cool for two minutes before refueling.
NOTICE

DO NOT use E15 or E85 fuel in this product. Engine or equipment damage caused by stale fuel or E85 E15 the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty. Only use unleaded gasoline containing up to 10% ethanol.

FUEL REQUIREMENTS

  • CLEAN, FRESH, unleaded gasoline, 87–93 octane.
  • Up to 10% ethanol (gasohol) is acceptable (where available; non-ethanol fuel is recommended).
  • DO NOT use E85 or E15.
  • DO NOT use a gas oil mix.
  • DO NOT modify the engine to run on alternate fuels.
  • DO NOT fuel indoors.
  • DO NOT create a spark or flame while fueling.

USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow the manufacturer's instructions for use.
ALWAYS mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator. Run the generator for five minutes to allow the stabilizer to treat the entire fuel system.

FILLING THE FUEL TANK

  1. Turn the generator OFF and allow to cool for a minimum of two minutes before fueling.
  2. Place the generator on level ground in a well-ventilated area.
  3. Clean area around fuel cap and remove the cap slowly.
    NOTICE
    Only fill the tank from an approved gasoline container. Make sure the gasoline container is internally clean and in good condition to prevent fuel system contamination.
  1. Slowly add the recommended fuel. DO NOT overfill. Fill only to the red maximum fill ring on the fuel screen filter visible in the filler neck.
    FILLING THE FUEL TANK
  2. Install the fuel cap.

NOTICE
Fuel can damage paint and plastic. Use caution when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty.
NOTICE
Clean the fuel screen filter of debris before and after each fueling. Remove the fuel screen filter by slightly compressing it while removing it from the fuel tank.

CONNECT THE BATTERY

A quick-connect battery plug is pre-installed on the battery. Remove the cable tie securing the plugs then push firmly to connect them.

Note: The generator is equipped with a battery charging feature. Once the engine is running, a small charge will slowly recharge the battery.

OPERATION

GENERATOR LOCATION

Read and understand all safety information before starting the generator.


Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

NEVER operate the generator inside any building, including garages, basements, crawlspaces, sheds, enclosure, or compartment, including the generator compartment of a recreational vehicle.


Electrocution hazard. NEVER use the generator in a location that is wet or damp. NEVER expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution

Fire hazard. Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could block cooling vents or the air intake system. Allow the generator to cool for 30 minutes before transport or storage.

The generator should be on a flat, level surface at all times (Even while not in operation). The generator must have at least 5 ft. (1.5 m) of clearance from all combustible material. DO NOT operate the generator in the back of a SUV, camper, trailer, truck bed (regular, flat, or otherwise), under stairs, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation.


Asphyxiation hazard. Place the generator in a wellventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning the generator.

GROUNDING


Shock hazard. Failure to properly ground the generator can result in electric shock.
NOTICE
Only use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.

The generator neutral is bonded to the frame. There is a permanent conductor between the generator (stator wire) and the frame. If this generator will be used only with cord and plug equipment connected to the receptacles mounted on the generator, National Electric Code does not require that the unit be grounded. However, other methods of using the generator may require grounding to reduce the risk of shock or electrocution.
Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.

DISCONNECTING THE BONDED NEUTRAL
The bonded neutral should only be removed under specific circumstances. Consult a qualified electrician to determine if your situation requires disconnecting the bonded neutral.

  1. Remove the alternator cover.
  2. Remove the bonded jumper wire and reinstall the nut.
    DISCONNECTING THE BONDED NEUTRAL - PART 1
  3. Remove the nut securing the neutral ground wire and attach the bonded jumper wire. Reinstall the nut.
    DISCONNECTING THE BONDED NEUTRAL - PART 2
  1. Reinstall the alternator cover.


Apply a new "NEUTRAL UNBONDED" Label over the "NEUTRAL BONDED TO FRAME" label on the front of the control panel.

HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes over 5,000 ft. (1524 m). Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions.
NOTICE
DO NOT operate the generator at altitudes below 2,000 ft. (762 m) with the high altitude kit installed. Engine damage may occur.
High Altitude Carburetor Kit Part# 518965

VOLTAGE SELECTOR SWITCH

The 120V/240V selector switch, which gives the user the ability to double the amperage in the generator for more demanding applications. The voltage selector switches the dual 120V AC windings of the generator to produce 120V or 240V. If a 240V appliance is connected to the 4-prong L14-30R receptacle, the switch must be in the "240V" position. The 120V only outlets will not output power when the Voltage Selector is in the 240V position.


Only change the Voltage Selector Switch with the generator OFF. DO NOT switch the voltage while the generator is running or powering appliances.

BEFORE STARTING THE GENERATOR

Verify that:

  • The generator is placed in a safe, appropriate location.
  • The generator is on a dry, flat, and level surface.
  • The engine is filled with oil.
  • All loads are disconnected.


Fire and explosion hazard. DO NOT move or tip the generator during operation.

STARTING THE ENGINE

  1. Verify that fuel is in the gas tank.
  1. Verify voltage selector switch is in the desired vo
  1. Turn the fuel selector switch on the control panel to gasoline operation.
  2. Turn the fuel tank valve to the ON position.

    Note: If cold starting, move the choke lever to the ON position.

  3. Choose the starting method:
    1. Push-Button Start: Push and hold the engine START/STOP button for two seconds.
    2. Recoil Start: Manually close the choke if the engine is cold. Firmly grasp and pull the recoil handle slowly until you feel increased resistance, then pull rapidly.
  4. After starting, allow the engine to run for several seconds then move the Choke lever to the fully OFF position.

STOPPING THE ENGINE

  1. Turn off and unplug all connected electrical loads.

    NEVER start or stop the generator with electrical devices connected.
  2. Let the generator run with no load for several minutes to stabilize internal temperatures of the engine.
  3. Push the Run/Stop switch to the Stop position.
    Note: Alternately, if the generator is used infrequently, turn the fuel tank valve to the OFF position to limit the residual fuel remaining in the carburetor float bowl. The engine will stop when fuel in the carburetor and fuel line is exhausted.

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent basis (more than one month before next use), refer to the Storage section of this manual for information regarding fuel deterioration.

AC CIRCUIT BREAKERS

The circuit breakers will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle.
If an AC circuit breaker switches OFF automatically, check that the appliance is working correctly and it does not exceed the rated load capacity of the circuit before resetting the AC circuit breaker ON.

GENERATOR CAPACITY

NOTICE
DO NOT overload the generator's capacity. Exceeding the generator's wattage/amperage capacity can damage the generator and/or electrical devices connected to it. Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the same time. The total power requirements (Volts x Amps = Watts) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model or serial number. To determine power requirements:

  1. Select the items you will power at the same time.
  1. Total the continuous (running) watts of these items. This is the amount of power the generator must produce to keep the items running. See the wattage reference chart.
  2. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Example:

Tool or Appliance Running Watts* Starting Watts*
RV Air Conditioner (11,000 BTU) 1010 1600
TV (Tube Type) 300 0
RV Refrigerator 180 600
Radio 200 0
Light (75 Watts) 300 0
Coffee Maker 600 0
2590 Total Running Watts* 1600 Highest Starting Watts*
Total Running Watts 2590
Highest Starting Watts + 1600
Total Starting Watts Needed 4190

*Wattages listed are approximate. Verify actual wattage.

POWER MANAGEMENT

To prolong the life of the generator and attached devices, use care when adding electrical loads to the generator. There should be nothing connected to the generator outlets before starting the engine. The correct and safe way to manage generator power is to sequentially add loads as follows:

  1. With nothing connected to the generator, start the engine as described in this manual.
  2. Plug in and turn on the first load, preferably the largest load you have.
  3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
  4. Plug in and turn on the next load.
  5. Again, permit the generator to stabilize.
  6. Repeat steps 4 and 5 for each additional load.

Wattage Reference

Tool or Appliance Estimated Running Watts* Estimated Starting Watts*
Incandescent Lights
(4 Quantity x 75 Watts)
300 0
TV (Tube Type) 300 0
Sump Pump (1/3 hp) 800 1300
Refrigerator or Freezer 700 2200
Well Pump (1/3 hp) 1000 2000
Furnace (1/2 hp) 800 2350
Radio 200 0
Drill (3/8", 4 amps) 440 600
Circular Saw (Heavy Duty, 7-1/4") 1400 2300
Miter Saw (10") 1800 1800
Table Saw (10") 2000 2000

*Wattages listed are approximate. Verify actual wattage.

EXTENSION CORDS

Asphyxiation hazard. Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings. If an extension cord running directly into your home is used to power indoor items, there is a risk of carbon monoxide poisoning to people inside the home. ALWAYS use battery-powered carbon monoxide detector (s) that meet current UL 2034 safety standards when running the generator. Regularly check the detector (s) battery.

Asphyxiation hazard. When operating the generator with extension cords, make sure the generator is located in an open, outdoor area, far away from occupied spaces with exhaust pointed away.

Fire and electrocution hazard. NEVER use worn or damaged extension cords. Damaged or overloaded extension cords could overheat, arc, and burn resulting in death or serious injury.
Before connecting an AC appliance or power cord to the generator:

  • Use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.
  • Make sure the tool or appliance is in good working order. Faulty appliances or power cords can create a potential for electric shock.
  • Make sure the electrical rating of the tool or appliance does not exceed the rated power of the generator or the receptacle being used.

EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for outdoor use that are rated for the electrical load.

Total Minimum Gauge, Outdoor Rated
Amperage Up to 50 FT (15 M) Up to 100 FT (30 M)
Up to 10A
Up to 15A
Up to 20A
Up to 30A
Up to 35A

TRANSPORTING


Weight hazard. ALWAYS have assistance when lifting the generator.

  • Allow the generator to cool a minimum of 30 minutes before transporting.
  • Replace all protective covers on the generator control panel.
  • Only use the generator's fixed frame to lift the unit or attach any load restraints such as ropes or tie-down straps. DO NOT attempt to lift or secure the generator by holding onto any of its other components.
  • Keep the unit level during transport to minimize the possibility of fuel leakage or, if possible, drain the fuel or run the engine until the fuel tank is empty before transport.

    Fire hazard. DO NOT up-end the generator or place it on its side. Fuel or oil can leak and damage to the generator may occur.

MAINTENANCE


Accidental start-up. Disconnect the spark plug boot from the spark plug when performing maintenance on the generator.

MAINTENANCE SCHEDULE

Regular maintenance will improve performance and extend the service life of the generator. Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions as noted below.

Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil1
Clean air filter2
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor Inspect/clean spark plug Fuel valve maintenance
Inspect/adjust valve clearance3
After 300 Hours or Every Year
Replace spark plug
Replace air filter

1 Change oil every month when operating under heavy load or in high temperatures.
2 Clean more often under dirty or dusty conditions.
Replace air filter if it cannot be adequately cleaned.
3 Recommend service to be performed by authorized Westinghouse service dealer.

MAINTENANCE REMINDERS

Maintenance reminder codes will be shown on the Data Display based on unit Lifetime Hours. The maintenance codes will be displayed until the unit is turned off.

Maintenance Code Required Maintenance
P25 Change engine oil
P50 Change engine oil, clean air filter
P100
  • Inspect/clean spark arrestor
  • Inspect/clean spark plug
  • Fuel valve maintenance
  • Inspect/adjust valve clearance

MAINTENANCE REPLACEMENT PARTS

Description Part Number
Air filter 5941
Oil drain plug crush washer 94007
Spark arrestor 6790
Spark plug 97108 (F7TC)
Battery, 9 AH 511008

AIR FILTER MAINTENANCE

The air filter must be cleaned after every 50 hours of use or six months (frequency should be increased if the generator is operated in a dusty environment).

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. Release the clips and remove the air filter cover.

  3. Clean the air filter with compressed air. Replace if damaged.
  4. Make sure the air filter and rubber cap are correctly installed. Install the air filter cover and secure it in place with the cover clips.

ENGINE OIL LEVEL CHECK


Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
NOTICE
ALWAYS use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.

When using the generator under dirty, dusty conditions or in extremely hot weather, change the oil more frequently.
Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions.
ENGINE OIL LEVEL CHECK - PART 1
Check the engine oil level before each use or every 8 hours of operation.

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. With a damp rag, clean around the oil dipstick.
  1. Remove the oil dipstick and wipe the dipstick clean.
    ENGINE OIL LEVEL CHECK - PART 2
  1. Insert the dipstick into the oil filler neck without screwing it in. Remove the dipstick and verify that the oil level is within safe operating range between the low (L) and high (H) marks on the dipstick.

  2. If low, add recommended engine oil incrementally and recheck until the level is between the L and H marks on the dipstick. DO NOT overfill. If over the H mark on the dipstick, drain the oil to reduce the oil level to the full mark.
  3. Replace the oil dipstick and hand-tighten.

ENGINE OIL CHANGE

When using the generator under dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Change the oil while the engine is still warm from operation.

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. With a damp rag, clean around the oil dipstick. Remove the dipstick and wipe clean.
  3. Place an oil pan (or suitable container) under the oil drain bolt.
  4. Using a 10mm wrench, remove the oil drain bolt and allow the oil the to drain.
    ENGINE OIL CHANGE
  5. Install the oil drain bolt and tighten securely.
    Note: A new oil drain plug crush washer is recommended at each oil change.
  6. Slowly pour oil into the oil filler neck until oil the level is between the L and H marks on the dipstick. Stop frequently to check the oil level. DO NOT overfill.
    Maximum oil capacity: 0.74 Quart (0.7 Liter)
  7. Install the oil dipstick and hand-tighten.

NOTICE
DO NOT pollute. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.

SPARK PLUG MAINTENANCE

Inspect and clean the spark plug after every 100 hours of use or six months. Replace the spark plug after 300 hours of use or every year.
NOTICE
ALWAYS use the Westinghouse OEM or compatible non-resistor-type spark plug. Use of resistor-type spark plug can result in rough idling, misfire, or may prevent the engine from starting.

  1. Place the generator on a level surface and allow the engine to cool.
  2. Remove the spark plug boot by firmly pulling the spark boot directly away from the engine.

  3. Clean the area around the spark plug.
  4. Remove the spark plug with the included spark plug socket wrench.
    NOTICE
    NEVER apply any side load or move the spark plug laterally when removing the spark plug.
  5. Inspect the spark plug. Replace if electrodes are pitted, burned, or the insulator is cracked. Only use a recommended replacement plug.
  6. Measure the spark plug electrode gap with a wire-type feeler gauge. If necessary, correct the gap by carefully bending the side electrode.
    Spark plug gap: 0.024 – 0.032 in. (0.60 – 0.80 mm)
    SPARK PLUG MAINTENANCE
  7. Carefully install the spark plug finger tight, then tighten as additional 3/8 to 1/2 turn with the spark plug wrench.
  8. Attach the spark plug boot.

SPARK ARRESTOR SERVICE

Allow the muffler to cool completely before servicing the spark arrestor. Check and clean the spark arrestor after every 100 hours of use or six months. Failure to clean the spark arrestor will result in degraded engine performance.

  1. Place the generator on a level surface.
  1. Slide in screwdriver into side slot and remove screw holding clamp (A) on spark arrestor. Pull out spark arrestor assembly.
    SPARK ARRESTOR SERVICE
  2. Carefully remove the carbon deposits from the spark arrestor screen with a wire brush. The spark arrestor must be free of breaks and tears. Replace the spark arrestor if damaged.
  3. Reinstall the spark arrestor.

FUEL VALVE MAINTENANCE
The fuel valve is equipped with a fuel sediment cup, screen, and o-ring. The fuel valve does not require servicing if the unit is properly maintained with fresh, clean fuel. If fuel- related troubleshooting is required, perform fuel valve maintenance.

  1. Allow the generator to cool completely.
  1. Turn the fuel valve to the OFF position.
  1. Remove the sediment cup from the fuel valve. Remove the o-ring and screen.

  1. Wash the sediment cup, o-ring, and screen in a nonflammable solvent. Dry thoroughly.
  1. Place the screen and o-ring into the fuel valve. Install the sediment cup and tighten securely.
  1. Turn the fuel valve to the ON position and check for leaks. Replace the fuel valve if there is any leakage.

BATTERY REPLACEMENT

Keep battery terminals covered at all times. The generator is shipped with a lithium ion (Li-Ion) battery. Exposed metal positive and negative terminals can short-circuit when they come into contact with metal objects, igniting the cell's internal materials and forcibly expelling burning contents, resulting in fires, explosions, serious injuries and even death.

Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly corrosive and poisonous. Wear protective clothing and eye protection when working near the battery. Keep children away from the battery.

Battery posts, terminals contain lead and lead compounds. Wash hands after handling.

  1. Loosen and remove the bolt on the battery hold-down plate and swing the plate out.
  2. Disconnect the quick-connect plugs and remove the battery from the unit.
  3. Disconnect the quick-disconnect cable leads from the battery.
  4. On the replacement battery, connect the white (-) quick- connect cable to the battery negative terminal. Slide the rubber boot over the connection hardware.
  5. Connect the red (+) quick-connect cable to the battery positive terminal. Slide the rubber boot over the connection hardware.
  6. Install the battery into the generator. Reinstall the battery hold-down plate and tighten the bolt.
  7. Connect the quick-connect plug.

NOTICE
Dispose of the used battery properly according to the guidelines established by your local or state government.

STORAGE

Proper storage preparation is required for trouble-free operation and generator longevity.

NOTICE
Gasoline stored for as little as 30 days can deteriorate, causing gum, varnish, and corrosive buildup in fuel lines, fuel passages, and the engine. This corrosive buildup restricts the flow of fuel, which can prevent the engine from starting after a prolonged storage period. The use of fuel stabilizer significantly increases the storage life of gasoline. Full-time use of fuel stabilizer is recommended. Follow the manufacturer's instructions for use.

STORAGE TIME RECOMMENDED PROCEDURE
Less than 1 month No service required.
2 to 6 months Fill with fresh gasoline and add gasoline stabilizer.
Drain the carburetor float bowl.
6 months or longer Drain the fuel tank and carburetor float bowl.

SHORT TERM STORAGE

  • Allow the generator to cool a minimum of 30 minutes before storage.
  • Replace all protective covers on the generator control panel.
  • Wipe the generator with a moist cloth. Clean any debris from the muffler cooling vents.
  • Store the generator in a well-ventilated, dry location away from sparks, open flames, pilot lights, heat, and other sources of ignition such as areas with a spark- producing electric motor or where power tools are operated.
  • DO NOT store the generator, or gasoline near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
  • With the engine and exhaust system cool and all surfaces dry, cover the generator to keep out dust. DO NOT use a plastic sheet as a dust cover. Non-porous materials trap moisture and promote rust and corrosion.

LONG TERM STORAGE
Even properly stabilized fuel can leave residue and cause corrosion if left long term. If storing the generator for two to six months, drain the float bowl to prevent gum and varnish buildup in the carburetor.

DRAINING THE FLOAT BOWL

  1. Turn the fuel tank valve to the OFF position.
  2. Locate the drain screw on the bottom of the carburetor float bowl.
    DRAINING THE FLOAT BOWL
  1. Place an appropriate gasoline container under the drain screw to catch the drained fuel.
  2. Loosen the float bowl drain screw and allow the fuel to drain. Tighten the float bowl drain screw.

DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain the fuel tank to prevent fuel separation, deterioration, and deposits in the fuel system.

  1. Unscrew the fuel tank cap. Remove the fuel screen filter by slightly compressing it while removing it from the tank.
  1. Using a commercially available gasoline hand pump (not included), siphon the gasoline from the fuel tank into an approved gasoline container. DO NOT use an electric pump.
  2. Reinstall the fuel screen filter and the fuel tank cap.
  3. Start the generator and allow it to run until the generator engine stops.
  4. Push the Run/Stop switch to the Stop position.
  5. Remove the spark plug.
  1. Put a teaspoon of engine oil into the cylinder and pull the recoil handle until resistance is felt. At this position the piston is coming up on its compression stroke and both valves are closed. Storing the engine in this position will help prevent internal corrosion. Return the recoil handle gently.
  2. Reinstall the spark plug. Leave the spark plug boot disconnected to prevent accidental starting.

VALVE CLEARANCE

NOTICE
Checking and adjusting valve clearance must be done when the engine is cold.

  1. Remove the rocker arm cover and carefully remove the gasket. If the gasket is torn or damaged, it must be replaced.
  2. Remove the spark plug so the engine can be rotated more easily.
  3. Rotate the engine to top dead center (TDC) by pulling the recoil handle slowly. Looking through the spark plug hole, the piston should be at the top (both valves are closed).
  4. Both the rocker arms should be loose at TDC on the compression stroke. If they are not, rotate the engine 360°.
  5. Insert a feeler gauge between the rocker arm and the valve stem to measure valve clearance.
    VALVE CLEARANCE
    Intake Valve Exhaust Valve
    Valve Clearance 0.0031 – 0.0047 in
    (0.08 – 0.12 mm)
    0.0051 – 0.0067 in
    (0.13 – 0.17 mm)
    Torque 8-12 N•m 8-12 N•m
  6. If an adjustment is necessary, hold the rocker arm pivot and loosen the pivot adjusting nut.
  7. Turn the rocker arm pivot to obtain the specified clearance. Hold the rocker arm pivot and re-tighten the pivot adjusting nut to the specified torque.
    Torque: 106 inch-pound (12 N•m)
  8. Perform this procedure for the other valve.
  9. Install the gasket, rocker arm cover, and spark plug.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTION

Engine will not start

Battery switch in the OFF position. Turn battery switch to the ON position.
Out of fuel. Refuel.
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Drain the fuel tank. Refuel with fresh gasoline.
Dirty air filter. Clean the air filter.
Low engine oil level stopped generator. If low oil LED illuminated, turn battery switch to the OFF position. Add engine oil.
Spark plug wet with fuel (flooded engine). Wait five minutes. Turn battery switch to the OFF position. Pull recoil handle rapidly several times. If the generator does not start, remove spark plug and dry.
Spark plug faulty, fouled, or improperly gapped. Gap or replace the spark plug. Reinstall.
Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Contact Westinghouse customer service toll- free at 1 (855) 944-3571.
Battery drained. Use the recoil handle to start the generator.
Charge the battery.
Choke partially open or closed due to weak or disconnected battery. Manually set the choke. See Maintenance section.

Engine starts, then shuts down

Out of fuel. Refuel.
Incorrect engine oil level. Check engine oil level.
Dirty air filter. Clean the air filter.
Contaminated fuel. Drain the fuel tank. Refuel with fresh gasoline.
Defective low oil level switch. Contact Westinghouse customer service toll- free at 1 (855) 944-3571.

Engine lacks power

Air filter restricted. Clean or replace air filter.
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline. Drain the fuel tank. Refuel with fresh gasoline.
Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Contact Westinghouse customer service toll- free at 1 (855) 944-3571.

Engine runs rough or bogs when load applied

Dirty air filter. Clean the air filter.
Generator overloaded. Unplug some devices.
Faulty power tool or appliance. Replace or repair tool or appliance. Stop and restart the engine.
Fuel filter restricted, fuel system malfunction, fuel pump failure, ignition malfunction, valves stuck, etc. Contact Westinghouse customer service toll- free at 1 (855) 944-3571.

No power at AC receptacles

AC circuit breaker/s tripped. Check AC loads and reset circuit breaker/s.
Faulty power tool or appliance. Replace or repair tool or appliance. Stop and restart the engine.
Faulty generator. Contact Westinghouse customer service toll- free at 1 (855) 944-3571.

EXPLODED VIEWS AND PARTS LISTS

EXPLODED VIEW A

EXPLODED VIEWS AND PARTS LISTS - PART 1

NO. Code Description
1 FRAME ASSEMBLY
1.1 774057-116 FRAME
1.2 531318 ISOLATION SUPPORT
1.3 90016 NUT M6
1.4 90018 NUT M8
1.5 91325 BOLT M6
1.6 91327 BOLT M6
1.7 544301 FRAME WIRE
1.8 96120 PAPER WASHER
1.9 530324-116 MOVABLE RECTANGLE PIPE
1.10 94002 TOOTH WASHER
2 BATTERY BRACKET ASSEMBLY
2.1 511008 BATTERY
2.2 542212-116 BATTERY HOLDER
2.3 91327 BOLT M6
2.4 512058 BATTERY WIRING ASSEMBLY
3 FOOT BRACKET ASSEMBLY
3.1 90023 NUT M6
3.2 91343 BOLT M8
3.3 525314-116 FOOT BRACKET ASSEMBLY
3.4 531115 FOOT BRACKET ISOLATION SUPPORT
3.5 91333 BOLT M6
4 ENGINE ASSEMBLY
4.1 1148275210024 ENGINE ASSEMBLY
4.2 91322 BOLT M5
4.3 539602 CRANKCASE COVER SHIELD
5 HANDLE WELDING ASSEMBLY
5.1 527613 HANDLE PLUG
5.2 527611 HANDLE MOUNTING BOLT
5.3 526639-116 HANDLE
5.4 528609 HANDLE RUBBER SLEEVE
6 CARBON CANNISTER ASSEMBLY
6.1 95021 CARBON CANISTER AND AIR FILTER CONNECTING PIPE
6.2 91327 BOLT M6
6.3 94402 FUEL LINE CLAMP
6.4 94408 FUEL LINE CLAMP
6.5 543601L CARBON CANISTER ASSEMBLY
6.6 95020 CARBON CANISTER AND FUEL TANK CONNECTING PIPE
6.7 94423 FUEL LINE CLAMP
7 PANEL ASSEMBLY
7.1 91327 BOLT M6
7.2 714360 PANEL ASSEMBLY
7.2.1 6022 ENGINE SWITCH
7.2.2 6041 TIME ACCUMULATOR
7.2.3 6508 VOLTAGE SELECTION SWITCH
7.2.4 6386 GROUND TERMINAL ASSEMBLY
7.2.5 6385 L14-30R RECEPTACLE
7.2.6 6848 WATERPROOF CAP
7.2.7 6441-22 THERMAL PROTECTOR
7.2.8 6015 RV SOCKET
7.2.9 6849 WATERPROOF CAP
7.2.10 6441-30 THERMAL PROTECTOR
7.2.11 6441-20 THERMAL PROTECTOR
7.2.12 6032 L5-20R RECEPTACLE
7.2.13 6846 WATERPROOF CAP
7.3 96120 PAPER WASHER
8 WHEEL ASSEMBLY
8.1 94224 FLAT WASHER
8.2 523308 WHEEL
8.3 524320 AXLE
8.4 548302 COTTER PIN
9 FUEL TANK ASSEMBLY
9.1 700271L-116 FUEL TANK
9.1.1 518801 FUEL TANK FILTER
9.1.2 6785 FUEL GAUGE
9.2 519215 FUEL CAP
9.3 91460 BOLT M6
9.4 518202 FUEL SWITCH
9.5 94403 FUEL LINE CLAMP
10 EXHAUST MUFFLER ASSEMBLY
10.1 90011 NUT M8
10.2 520308 MUFFLER MOUNTING BRACKET
10.3 91343 BOLT M8
10.4 96252 EXHAUST GASKET
10.5 94206 SPRING WASHER
10.6 705658 MUFFLER
10.6.1 6790 SPARK ARRESTER
11 ALTERNATOR ASSEMBLY
11.1 755537 ALTERNATOR
11.2 599019 CARBON BRUSH
11.3 6560 TERMINAL ASSEMBLY
11.4 532306 ALTERNATOR TAIL BRACKET
11.5 96813 GASKET
11.6 91721 BOLT M10
11.7 91619 BOLT M6
11.8 91322 BOLT M5
11.9 534301 AVR
11.10 533302-221 ALTERNATOR TAIL COVER
11.11 544604 SHORT WIRE
11.12 91513 BOLT M5
11.13 90009 NUT M5
11.14 532303-052 TAIL BRACKET FIXING PLATE
11.15 94204 SPRING WASHER
11.16 91323 BOLT M5
12 99616 OIL BOTTLE
13 99010 SPARK PLUG WRENCH
14 500942 FUNNEL
15 99025 WRENCH

EXPLODED VIEW B

EXPLODED VIEWS AND PARTS LISTS - PART 2

NO. Code Description
1 CRANKCASE ASSEMBLY
1.1 400202 CRANKCASE
1.2 93509 CRANKCASE OIL SEAL
1.3 93520 SWING ROD OIL SEAL
1.4 403901 RACKING BAR
1.5 96804 SWINGING ROD GASKET
1.6 383902 RETAINING CLIP
1.7 245106 OIL SENSOR
1.8 91329 BOLT M6
1.9 404301 CENTRIFUGAL GOVERNOR GEAR ASSEMBLY
1.10 93012 BEARING
1.11 240801 CABLE CLIP
1.12 245104 OIL PROTECTOR
1.13 91325 BOLT M6
2 CAMSHAFT
2.1 402002 CAMSHAFT
2.2 406101 VALVE LIFTER
2.3 401901 PUSH ROD
3 400301 CRANKSHAFT
4 CRANKCASE COVER ASSEMBLY
4.1 93509 CRANKCASE OIL SEAL
4.2 240904 CRANKCASE LOCATING PIN
4.3 96222 CRANKCASE SEAL WASHER
4.4 400101 CRANKCASE COVER
4.5 91347 BOLT M6
4.6 245601-295 DIPSTICK ASSEMBLY
4.7 93012 BEARING
5 SPEED CONTROL BRACKET ASSEMBLY
5.1 91329 BOLT M6
5.2 404001 SPEED REGULATING ARM
5.3 91822 BOLT M6
5.4 90016 NUT M6
5.5 402701 THROTTLE LEVER
5.6 404201 SPRING C
5.7 404101 SPRING B
5.8 407701 SPEED CONTROL BRACKET
6 LOWER GUARD ASSEMBLY
6.1 407601 UNDER GUARD
6.2 91325 BOLT M6
7 50130014 SHROUD ASSEMBLY
7.1 407501 WIND-LEAD-COVER
7.2 91325 BOLT M6
8 97108 SPARK PLUG
9 CYLINDER HEAD COVER ASSEMBLY
9.1 91329 BOLT M6
9.2 96225 CYLINDER HEAD COVER SEAL WASHER
9.3 401102 CYLINDER HEAD INTERNAL COVER
9.4 96226 CYLINDER HEAD INTERNAL COVER
SEAL WASHER
9.5 401101 CYLINDER HEAD COVER
9.6 92036 SCREW
9.7 95603 BLAST PIPE
9.8 94435 BLAST PIPE CLIP
10 CYLINDER HEAD ASSEMBLY
10.1 401002 CYLINDER HEAD
10.2 401701 INTAKE VALVE
10.3 405901 EXHAUST VALVE
10.4 406001 VALVE SPRING
10.5 402101 ROCKING ARM
10.6 91818 BOLT M6
10.7 402201 VALVE RETAINER ASSEMBLY
10.8 241806 VALVE SEAL
10.9 241817 VALVE SPRING RETAINER
10.10 329930 VALVE LOCK CLAMP
10.11 241804 TOP CAP
10.12 91022 DOUBLE END BOLT M6
10.13 91007 DOUBLE END BOLT M6
10.14 260901 CYLINDER HEAD LOCATING PIN
10.15 96223 CYLINDER HEAD GASKET
10.16 91452 BOLT M6
10.17 96235 GASKET
10.18 402301 CARBURETOR CONNECTION BLOCK
11 PISTON & PISTON RING ASSEMBLY
11.1 401201 PISTON
11.2 401601 PISTON RING ASSEMBLY
11.3 401501 CONNECTING ROD ASSEMBLY
11.4 405501 PISTON PIN
11.5 241301 PISTON PIN RING
12 CARBURETOR ASSEMBLY
12.1 94403 FUEL HOSE CLIP
12.2 402801-295 CARBURETOR ASSEMBLY
12.3 95727L FUEL HOSE
13 50030057 AIR FILTER ASSEMBLY
13.1 91329 BOLT M6
13.2 90016 NUT M6
13.3 402901 AIR FILTER ASSEMBLY
13.3.1 5941 FILTER ELEMENT
14 IGNITOR ASSEMBLY
14.1 97514 IGNITOR
14.2 91331 BOLT M6
15 50180021 FLYWHEEL ASSEMBLY
15.1 244508 STARTER PULLY
15.2 240413 FLYWHEEL
15.3 404601 IMPELLER
15.4 90003 NUT M6
16 RECOIL STARTER ASSEMBLY
16.1 91325 BOLT M6
16.2 404707-221A STARTER ASSEMBLY
16.2.1 5943 PULL
16.2.2 5942-221 START PULLER
16.3 260801 CABLE CLIP
17 STARTER MOTOR ASSEMBLY
17.1 97459 STARTING MOTOR
17.2 240910 LOCATING PIN
18 91816 BOLT M6
19 94007 OIL DRAIN BOLT WASHER
20 96224 GASKET
21 94324 STEEL WASHER

SCHEMATICS

SCHEMATICS

DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer service at 855-944-3571.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Westinghouse WGen5300s - Gasoline Portable Generator Manual

Advertisement

Need Assistance?

Do you have a question about the WGen5300s that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents