5. TECHNICAL DATA AND CHARACTERISTICS

Table. 9 - Legend - figures cap. 5
7 Gas inlet - Ø 1/2"
10 System delivery - Ø 3/4"
11 System return - Ø 3/4"
14 Pressure relief valve
16 Fan
22 Main burner
32 Heating circulating pump
36 Automatic air vent
44 Gas valve
72 Room thermostat (not supplied)
81 Ionisation/ignition electrode
95 Diverter valve (not supplied)
114 Water pressure switch
5.1 General view
196
22
81
278
16
95
10
44
fig. 26 - General view
5.2 Diagrams
H [m H
O]
2
9
C
8
7
6
5
4
3
2
1
B
0
0
500
1.000
fig. 27 - Circulating pump head / pressure losses
A = Boiler pressure losses - 1 = Circulating pump min. speed - 2 = Cir-
culating pump max. speed
40
EN
https://tm.by
Интернет-магазин TM.by
138 External probe (optional)
139 Remote timer control (optional)
154 Condensate drain pipe
155 Hot water tank temperature probe
186 Return sensor
191 Fume temperature sensor
193 Trap
196 Condensate tray
256 Modulating heating circulating pump signal
278 Double sensor (Safety + Heating)
A Auxiliary contact
191
186
14
193
36
114
32
7
11
A
1.500
2.000
Q [l/h]
cod. 3541G103 - Rev. 00 - 05/2017
BLUEHELIX TECH S 45H
5.3 Hydraulic circuit
278
10
5.4 Technical data table
Data
Max. heating capacity
Min. heating capacity
Max. Heat Output in heating (80/60°C)
Min. Heat Output in heating (80/60°C)
Max. Heat Output in heating (50/30°C)
Min. Heat Output in heating (50/30°C)
Gas supply pressure G20
Max. gas flow G20
Min. gas flow G20
CO
max. G20
2
CO
min. G20
2
Gas supply pressure G31
Max. gas flow G31
Min. gas flow G31
CO
max. G31
2
CO
min. G31
2
Efficiency class Directive 92/42 EEC
NOx emissions class
Max. working pressure in heating
Min. working pressure in heating
Max. heating temperature
Heating water content
Protection rating
Power supply voltage
Electrical power input
2.500
Empty weight
Type of unit
PIN CE
193
154
114
32
11
fig. 28 - Hydraulic circuit
Unit
BLUEHELIX TECH S 45H
kW
43.0
kW
7.5
kW
41.8
kW
7.3
kW
46.1
kW
8.1
mbar
20
3
4.55
m
/h
3
0.79
m
/h
%
9.30
%
8.80
mbar
37
kg/h
3.34
kg/h
0.58
%
10.5
%
9.70
-
-
5
bar
4.5
bar
0.8
°C
90
litres
4.8
IP
X5D
V/Hz
230V/50Hz
W
172
kg
35
C13-C23-C33-C43-C53-C63-C83-B23-B33
0461CM0988
186
36
14
(Q)
(Q)
(P)
(P)
(NOx)
(PMS)
(tmax)

Advertisement