Introduction
The RT510BC+ thermostat will switch your heating system on or off, as needed, in accordance
with the time and temperature set by you. It can be used with the RXBC605 integral plug-in RF
boiler control. The RF boiler control is a direct replacement for the basic time clock or blanking
plate usually supplied with the boiler. Installing the RF boiler control takes minutes. Once
installed, you will benefit from all the control features of the RT510BC+ thermostat.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
Box content
Desk Stand
RT510BC+
RXBC605
Box content
RXBC605 User Controls
LED - It will be on when the thermostat is demanding
heat.
RT510BC
SYNC Button - This is used only for pairing the RF
communications.
Mode Switch
RT510TX
Desk Stand
RXBC605
The AUTO
/ MANUAL
Boiler Control manually if required.
RXBC605 Switch Position
2 x AA Alkaline
1. AUTO mode. When the switch
Quick Guide
2 x Fixing Screws
Batteries
on the Boiler Control is in the AUTO
(normal) position, the Boiler Control
will automatically receive the RF signal
Quick Guide
from the transmitter and control the
RXBC605 Installation
boiler based on the programming of
2 x AA Alkaline
the transmitter.
Quick Guide
2 x Fixing Screws
2. MANUAL mode. The user
i
When the thermostat is operating in
Batteries
can also move the switch to the
NORMAL mode, if the Boiler Control has
MANUAL position; when in this
not received a signal from the transmitter
mode, the boiler will be always turned
after 1 hour, the Boiler Control will turn
on and the LED indicator will also
off the boiler, and the LED indicator will
be lit constantly. The manual mode
flash constantly (two times every second).
is only to be used as a temporary
Once the Boiler Control receives a valid
control if problems develop with the
ON or OFF signal, the Boiler Control will
control the heating system accordingly.
communication from the thermostat.
RT510TX Button Functions
RXBC605 Installation
Key
Function
1. Press once to activate Frost Mode
1
Remove the front panel from the boiler.
2. Press for 3 seconds in order to activate Holiday Mode
+Hr
Press once to activate/deactivate Boost function
2
Pull out the mechanical timer.
Press once to enter/exit Permanent Override function
3
Do not remove boiler loop.
Increase button
4
Connect the electrical plug.
Decrease button
SELECT
Select the clock or programme settings
5
Push fit boiler control into housing.
Introduction
SET
Press to confirm your settings
The RT510TX thermostat will switch your heating system on or off, as needed, in accordance
6
Replace the front panel ensuring a good seal is made.
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
with the time and temperature set by you. It can be used with the RXBC605 integral plug-in RF
7
Power up the boiler and check the correct operation.
boiler control. The RF boiler control is a direct replacement for the basic time clock or blanking
+
+
Press the buttons for 3 seconds to enter Installer Mode
plate usually supplied with the boiler. Installing the RF boiler control takes minutes. Once
installed, you will benefit from all the control features of the RT510TX thermostat.
SELECT
Press the buttons for 3 seconds to enter Clock Settings
+
Product Compliance
SET
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
RXBC605 Wiring Terminals
available on www.saluslegal.com
RT510TX Dip Switch Settings
868.0-868.6MHz; <13dBm
Terminal
Identifier
Description
The DIP Switches can be found on the rear of your thermostat.
Safety Information
1
N
Neutral
Control feature
TPI
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
2
L
Live input (230V AC)
Operation
When TPI is selected on DIP
your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and
switch № 2, the DIP switch
installation must comply with the guidance, standards and regulations applicable to the city, country or
3
COM
Common terminal (volt free)
№ 1 is functional. You can
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
choose the Cycles Per Hour
4
N.O.
Normally Open
between a lower comfort
Always isolate the AC Mains supply before installing or working on any components
level (6CPH) and a higher
that require 230 VAC 50Hz supply.
comfort level (9CPH).
1
Remove the front panel from the boiler.
2
Pull out the mechanical timer.
3
Do not remove boiler loop.
4
Connect the electrical plug.
5
Push fit boiler control into housing.
6
Replace the front panel ensuring a good seal is made.
7
Power up the boiler and check the correct operation.
RXBC605 Wiring Terminals
Terminal
Identifier
Description
1
N
Neutral
2
L
Live input (230V AC)
3
COM
Common terminal (volt free)
4
N.O.
Normally Open
RXBC605 User Controls
LED - It will be on when the thermostat is demanding
heat.
SYNC Button - This is used only for pairing the RF
communications.
Mode Switch
The AUTO
/ MANUAL
Boiler Control manually if required.
Test the Pairing Process
i
During test pairing, boiler control should flash confirming pair. If not, please follow
Pairing Process.
switch allows you to turn on the
+Hr
+Hr
TEST / PAIRING
SELECT
SET
SELECT
SET
RXBC605 Switch Position
TEST / PAIRING
i
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
1. AUTO mode. When the switch
The LED will start flashing red.
1
2
on the Boiler Control is in the AUTO
Pairing Process
1
Press the SYNC button for 3
(normal) position, the Boiler Control
2
The LG+5V is ready to be paired
seconds until LED starts flashing.
with your thermostat.
will automatically receive the RF signal
from the transmitter and control the
3 Sec
boiler based on the programming of
the transmitter.
3
Begin the pairing process
+Hr
+Hr
TEST / PAIRING
i
SELECT
3 Sec
SET
TEST / PAIRING
SELECT
SET
2. MANUAL mode. The user
When the thermostat is operating in
4
End the pairing process
can also move the switch to the
NORMAL mode, if the Boiler Control has
MANUAL position; when in this
+Hr
+Hr
not received a signal from the transmitter
Span
3 Sec
TEST / PAIRING
mode, the boiler will be always turned
TEST / PAIRING
SELECT
SET
SELECT
SET
When Span is selected
after 1 hour, the Boiler Control will turn
i
on DIP switch № 2,
Once the LED stops flashing, press the
Once paired please close the
the DIP switch № 1 is
TEST / PAIRING button for 3 sec.
on and the LED indicator will also
boiler control panel.
not functional.
The
off the boiler, and the LED indicator will
temperature accuracy of
your thermostat is set to
± 0.25 °C.
be lit constantly. The manual mode
flash constantly (two times every second).
is only to be used as a temporary
Once the Boiler Control receives a valid
control if problems develop with the
ON or OFF signal, the Boiler Control will
control the heating system accordingly.
communication from the thermostat.
RT510BC+ (Thermostat) Button Functions
Key
Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
+Hr
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
SELECT
Press to confirm your settings
SET
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
+
+
Press the buttons for 3 seconds to enter Installer Mode
SELECT
Press the buttons for 3 seconds to enter Clock Settings
+
SET
RT510BC+ (Thermostat) Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat. For all plug-in
boiler receiver applications ensure SW1 is set to RAD.
ON
ON
Control feature
ITLC
NA
SPAN
Operation
ITLC Internal Temperature
Load Compensation for
improved efficiency.
RAD
ITLC
1
2
Test the Pairing Process
i
During test pairing, boiler control should flash confirming pair. If not, please follow
Pairing Process.
switch allows you to turn on the
+Hr
TEST / PAIRING
SELECT
SET
i
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
1
2
Pairing Process
Press the SYNC button for 3
1
seconds until LED starts flashing.
3 Sec
3
Begin the pairing process
+Hr
3 Sec
TEST / PAIRING
SELECT
SET
End the pairing process
4
+Hr
3 Sec
TEST / PAIRING
SELECT
SET
SPAN
When Span is selected
Once the LED stops flashing, press the
on DIP switch № 2, the
TEST / PAIRING button for 3 sec.
DIP switch № 1 is not
functional.
+Hr
SELECT
SET
TEST / PAIRING
The LED will start flashing red.
2
The LG+5V is ready to be paired
with your thermostat.
+Hr
TEST / PAIRING
SELECT
SET
+Hr
TEST / PAIRING
SELECT
SET
i
Once paired please close the
boiler control panel.

Advertisement

loading

Summary of Contents for Salus RT510BC+

  • Page 1 Box content RXBC605 User Controls Test the Pairing Process LED - It will be on when the thermostat is demanding heat. During test pairing, boiler control should flash confirming pair. If not, please follow RT510BC+ Pairing Process. SYNC Button - This is used only for pairing the RF Boiler communications.
  • Page 2 Setting Time and Date Permanent Override Holiday Mode 3sec TEST / PAIRING TEST / PAIRING SELECT SELECT TEST / PAIRING TEST / PAIRING TEST / PAIRING SELECT SELECT SELECT SELECT TEST / PAIRING SELECT TEST / PAIRING SELECT TEST / PAIRING 3 Sec 3 Sec Press UP or DOWN to select the hour format...