Download Print this page

Mitsubishi Electric MELSEC-F FX3U-232ADP-MB Installation Manual page 3

Advertisement

JY997D26401G
Side
JAPANESE
A
Side
ENGLISH
B
FX
-232ADP-MB
3U
Installation Manual
Manual Number
JY997D26401
Revision
G
Date
November 2016
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
MODBUS
is a registered trademark of Schneider Electric SA.
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective November 2016
Specifications are subject to change without notice.
©
2007 Mitsubishi Electric Corporation
Safety Precautions
(Read these precautions before use.)
This manual classify the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
Explains FX
3S
JY997D48601
FX
Series User's Manual
specification details for I/O,
3S
MODEL CODE:
- Hardware Edition
w i r i n g , i n s t a l l a t i o n , a n d
09R535
maintenance.
Explains FX
3G
JY997D31301
FX
3G
Series User's Manual
specification details for I/O,
MODEL CODE:
w i r i n g , i n s t a l l a t i o n , a n d
- Hardware Edition
09R521
maintenance.
Explains FX
3GC
JY997D45401
FX
Series User's Manual
3GC
specification details for I/O,
MODEL CODE:
- Hardware Edition
w i r i n g , i n s t a l l a t i o n , a n d
09R533
maintenance.
Explains FX
3U
JY997D16501
FX
Series User's Manual
specification details for I/O,
3U
MODEL CODE:
- Hardware Edition
w i r i n g , i n s t a l l a t i o n , a n d
09R516
maintenance.
Explains FX
3UC
JY997D28701
FX
3UC
Series User's Manual
specification details for I/O,
MODEL CODE:
- Hardware Edition
w i r i n g , i n s t a l l a t i o n , a n d
09R519
maintenance.
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
FX
Series
JY997D16601
Describes PLC programming
3UC
Programming Manual
MODEL CODE:
for basic/applied instructions
- Basic & Applied Instruction
09R517
and devices.
Edition
Describes N:N link, parallel
JY997D16901
FX Series User's Manual
link, computer link, no
MODEL CODE:
- Data Communication Edition
protocol communication by
09R715
RS instructions/FX
FX
(D, DS, DSS) Series PLC
3UC
Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.
(ch2)
(ch1)
FX
-
FX
-
Analog
Analog
3U
Analog
Analog
3U
232ADP
232ADP
Main unit
special
special
special
special
adapter
adapter
-MB
adapter
adapter
-MB
3. Installation
For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.
INSTALLATION
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl
, H
S, SO
, or NO
), flammable gas, vibration
2
2
2
2
or impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• When drilling screw holes or wiring, make sure that cutting and wiring debris
do not enter the ventilation slits of the PLC.
Failure to do so may cause fire, equipment failures or malfunctions.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
• Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.
3.1 Connection to the PLC
This section describes the connection method to the PLC (FX
Series PLC is
3U
used for the following example).
For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.
Procedure
1) Turn off the power.
Disconnect all the cables connected to the PLC main unit and special adapter.
Dismount the main unit and special adapter mounted on DIN rail or mounted
directly using screws.
2) Install an expansion board to the main unit.
For installation of expansion board, refer to the following manual:
→ FX
Series User's Manual - Hardware Edition
3U
3) Remove the special adapter connector cover
on the expansion board (Right fig.A).
In case of connecting this product to another
special
adapter,
please
replace
the
4)
'expansion board' in the above description
with a 'special adapter' and perform the
procedure as indicated.
B
3)
4) Slide the special adapter slide lock (Right
fig.B) of the main unit.
In case of connecting this product to another
special adapter, please replace the 'main
A
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated. (Please replace the following
procedures similarly.)
5) Connect the
B
special adapter
(Right fig.C) to
C
the main unit as
6)
shown on the
right.
6) Slide back the
special adapter
5)
slide lock (Right
fig.B) of the main
unit to fix the
5)
special adapter
(Right fig.C).
5)
Connection precautions
Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of a
communication or analog special adapter.
Side
B
Manual name
Manual No.
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/
FX
Series User's Manual
3UC
JY997D26201
- MODBUS Serial
Communication Edition
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi Electric
dealer from where you purchase your product.
Applicable standards
FX
3U
-232ADP-MB
units made in April, 2007 or later comply with the EC Directive
(EMC Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.
→ FX
Series Hardware Manual (Manual No. JY997D48301)
3S
→ FX
Series Hardware Manual (Manual No. JY997D46001)
3G
→ FX
Series Hardware Manual (Manual No. JY997D45201)
3GC
→ FX
Series Hardware Manual (Manual No. JY997D50301)
3U
→ FX
(D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)
3UC
→ FX
-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)
3UC
Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Attention
This product is designed for use in industrial applications.
1. Outline
The FX
-232ADP-MB communication special adapter (hereinafter called 232ADP-
3U
MB) is a special adapter for RS-232C communication with an 9-pin D-Sub connector.
232ADP-MB is an isolated signal exchange unit of the RS-232C serial data
communication between the PLC and RS-232C device.
The FX
-232ADP-MB features all functionality that is available with the FX
3U
232ADP, except that it also has MODBUS communication available.
1.1 Communication Function
Communication type
Data transfer via dedicated protocol between PLC and
Computer link
computer (specified as the master station).
Non-protocol
Serial communication via non-protocol between PLC and
communication
RS-232C device.
Programming
Optional port available for suitable programming tool when
communication
232ADP-MB is connected to PLC.
Program transfer or monitoring enabled via modem and
may also
Remote maintenance
phone line connected to serial port of PLC.
MODBUS
Data transfer between a master and a slave.
communication
1.2 Incorporated Items
Series PLC
Verify that the following product and items are included in the package:
Product
FX
-232ADP-MB communication special adapter
3U
Accessories
Installation manual (This manual)
Series PLC
Series PLC
Series PLC
Series PLC
-232IF.
2N
4. Wiring
For wiring details, refer to the following manual.
→ FX Series User's Manual - Data Communication Edition
→ FX
/FX
/FX
3S
3G
3GC
- MODBUS Serial Communication Edition
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
• When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Make sure to observe the following precautions in order to prevent any damage to
the machinery or accidents due to abnormal data written to the PLC under the
influence of noise:
- Do not bundle the main circuit line together with or lay it close to the main
circuit, high-voltage line or load line.
Otherwise, noise disturbance and/or surge induction are likely to take place.
As a guideline, lay the control line at least 100mm (3.94") or more away from
the main circuit or high-voltage lines.
5. Specification
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric representative.
• Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
• The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. Failure to do so may cause failures in the
product. After transportation, verify operation of the product and check for damage
of the mounting part, etc.
5.1 Applicable PLC
Model name
FX
Series PLC
Ver. 1.00 or later for all communication functions
3S
Ver. 1.30 or later for MODBUS communication
FX
Series PLC
Ver. 1.00 or later for all communication functions except
3G
MODBUS
FX
Series PLC
Ver. 1.40 or later for all communication functions
3GC
4)
Ver. 2.40 or later for MODBUS communication
FX
Series PLC
Ver. 2.20 or later for all communication functions except
3U
MODBUS
Ver. 2.40 or later for MODBUS communication
FX
3UC
Series PLC
Ver. 1.00 or later for all communication functions except
B
MODBUS
The version number can be checked by monitoring D8001/D8101, as well the last three
digits indicate the version number.
5.2 General Specifications
Items other than the following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC User's manual Hardware Edition.
Item
Specification
6)
Dielectric withstand
500 V AC, one minute
voltage
5 MΩ or higher by 500 V
Insulation resistance
DC insulation resistance
tester
B
1.3 External Dimensions and Part Names
Description
[3]
Explains the MODBUS serial
communication network.
[2]
[1]
7(0.28")
Special adapter
connector cover
is removed
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock:
-
3U
Used to connect special adapter on left side of this special adapter.
[4] Special adapter connector cover:
Remove this cover for connecting special adapter on the left side.
[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
Not used when connecting to FX
Function
[6] POWER LED (green): Lit while 5 V DC power is supplied from main unit.
[7] RD LED (red):
Lit while receiving data from connected RS-232C device.
[8] SD LED (red):
Lit while sending data to connected RS-232C device.
[9] Special adapter connector:
Used to connect this special adapter to PLC main unit or special adapter.
[10] RS-232C connector (9-pin D-Sub, male):
Connect RS-232C device to this RS-232C connector
[11] Screws to fix a cable connector: Screw holes #4-40UNC (inch screw thread)
[12] DIN rail mounting hook
[13] Special adapter fixing hook
[14] Special adapter connector:
Used to connect communication special adapter or analog special adapter to
this adapter on left side.
1.4 Pin Configuration
The pin configuration of the RS-232C port on the 232ADP-MB is as shown below.
Screws to fix
Pin
RS-232C
No.
connector
1
5
9
2
6
1
3
Screw holes:
#4-40UNC
(inch screw
4
thread)
5
6
7,8,9 Not used
5.3 Power Supply Specification
Item
/FX
/FX
Series User's Manual
3
U
3UC
Current consumption
5.4 Performance Specification
Item
Transmission
standard
Type of isolation
Transmission
distance
Connection method
Number of occupied
I/O points
Communication
method
Baud rate
Communication
format
LED display:
LED color
*1 Applicable for FX
/FX
3U
Series PLC.
*2 When you set the baud rate to 38400 bps or more in a FX
PLC, please set D8411 (D8431) to be 3 ms or more. When D8411 (D8431) is set
at less than 3 ms, it may not be able to communicate normally.
*3 Applicable for products manufactured in July, 2012 or later (manufacturer's serial
number: 127**** or later). The year and month of production of the special
adapter can be checked from the manufacturer's serial number "S/N" indicated
on the label.
For manufacturer's serial number, refer to the following manual.
→ FX
Applicability
6. 「电器电子产品有害物质限制使用标识要求」的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品
 本产品中所含有的有害6物质的名称, 含有量, 含有部品如下表所示。
部件名称
外壳
可编程
控制器
印刷基板
本表格依据SJ/T 11364的规定编制。
B e t w ee n t e rm in a l b l oc k a nd
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规
ground terminal of PLC main unit
定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
2. Channel Allocation
Up to two communication ports can be added to the main unit.
[13]
[4]
Refer to the following manual for equipment that occupies communication ports.
[5]
[6]
[7]
FX
[8]
Communication port channels are automatically allocated.
[9]
[10]
[11]
FX
Communication port channels are automatically allocated.
• 40-point, 60-point type
7.5
74(2.92")
15.1
(0.29")
[12]
(0.6")
[14]
17.6
(0.7")
Weight: Approx. 80 g (0.18 lbs)
3GC
/FX
3UC
Series PLC.
• 14-point, 24-point type
FX
Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.
Signal
Name
Function
FX
Receive
ON when carrier for data reception
CD
Communication port channels are automatically allocated. The communication
carrier
is detected.
(DCD)
special adapter closer to the main unit is ch1.
detection
(RS-232C device to 232ADP-MB)
• Using one communication special adapter + communication expansion board
RD
Receive
Receive data
(RXD)
data
(RS-232C device to 232ADP-MB)
SD
Send data
Send data
(TXD)
(232ADP-MB to RS-232C device)
ON when RS-232C device is ready
ER
Send
to receive data.
(DTR)
request
(232ADP-MB to RS-232C device)
SG
Signal
Signal ground
• Using two communication special adapters
(GND)
ground
(232ADP-MB to RS-232C device)
ON when send request is made
DR
Send
toward RS-232C device.
(DSR)
enable
(RS-232C device to 232ADP-MB)
Specification
30 mA
5 V DC power is supplied internally from the main unit.
Specification
Conforming to RS-232C
Photocoupler isolation
15 m (49' 2") or less
9-pin D-Sub connector (male)
0 point (This number is not related to the maximum number
of input/output points of the PLC.)
Full-duplex
Computer link, and Non-protocol Items other than the
following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC
User's manual Hardware Edition.:
*1
300/600/1200/2400/4800/9600/19200/38400
bps
Programming communication:
9600/19200/38400/57600/115200 bps
Remote maintenance: 9600 bps
*2
MODBUS communication
:
*3
*3
300/600/1200/2400/4800/9600/19200/38400
/57600
/
*3
115200
bps
Computer link (dedicated protocol: format 1/format 4),
Non-protocol, Programming communication, Remote
maintenance, and MODBUS communication
Power: green, RD: red, SD: red
Series PLC Ver. 2.41 or later and FX
/FX
/FX
3UC
3S
3G
3GC
/FX
/FX
Series
3S
3G
3GC
/FX
/FX
/FX
/FX
SERIES USER'S MANUAL
3S
3G
3GC
3U
3UC
- MODBUS Serial Communication Edition
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
产品中有害物质的名称及含量
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
有害物质
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for
多溴
六价铬
多溴联苯
二苯醚
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBB)
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
(PBDE)
×
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
→ FX Series User's Manual - Data Communication Edition
Series PLC
3S
(ch1)
FX
-
Analog
FX
-
3U
3S
232ADP
special
CNV-ADP
Main unit
-MB
adapter
Series PLC
3G
(ch2)
(ch1)
Analog
FX
-
Analog
FX
-
FX
-
3U
3U
3G
special
special
Main unit
232ADP
232ADP
CNV-ADP
adapter
adapter
-MB
-MB
(ch1)
Communication
expansion board (ch2)
Analog
FX
-
Analog
FX
-
3U
3G
Main unit
special
232ADP
special
CNV-ADP
adapter
-MB
adapter
(ch1)
FX
-
FX
-
Analog
3G
3U
CNV-ADP
232ADP
special
Main unit
-MB
adapter
Series PLC
3GC
(ch2)
(ch1)
Analog
FX
-
Analog
FX
-
3U
3U
special
232ADP
special
232ADP
Main unit
-MB
-MB
adapter
adapter
/FX
-32MT-LT(-2) Series PLC
3U
3UC
Communication
(ch2)
expansion board (ch1)
Analog
Analog
FX
-
Analog
Analog
3U
special
special
232ADP
special
special
Main unit
adapter
adapter
-MB
adapter
adapter
(ch2)
(ch1)
FX
-CNV-BD
3U
Analog
Analog
FX
-
Analog
Analog
FX
-
3U
3U
Main unit
special
special
232ADP
special
special
232ADP
adapter
adapter
-MB
adapter
adapter
-MB
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
accidents, and compensation for damages to products other than Mitsubishi products.
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.

Advertisement

loading

This manual is also suitable for:

Melsec-f fx3u