General Safety Warnings; Technical Characteristics - Baxi 11p Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

GENERAL SAFETY WARNINGS

The Operation Manual is an integral part of the product and so must
be carefully preserved in order to accompany the product; if it is
lost or damaged another copy can be requested from the Technical
Assistance Centre.
The installation of the device and any other repairs or mainte-
nance must be performed by qualified personnel according to
the law in force, in compliance with the installing regulations
including any revisions.
It is recommended that trained personnel install the device.
The device must be used according to the manufacturer spe-
cifications. The manufacturer cannot be held contractually or
otherwise responsible for damage caused to persons, ani-
mals or objects as a result of incorrect installation, repair or
maintenance or improper usage.
The product's safety or automatic regulation devices must not
be modified unless performed by the manufacturer.
This device is intended for heating water and therefore must
be connected to a water distribution network who's load and
settings are compatible with the product.
If water spills, turn off the water supply and advise the quali-
fied personnel at the Technical Assistance Centre.
If the machine is not used for prolonged periods turn off the
gas supply. If there is a risk of the water freezing, empty the
water heater.
If the machine breaks down or does not function properly,
deactivate it, do not attempt to perform any repairs.
The machine's maintenance must be performed at least once
a year: Book a maintenance session with the Technical Assi-
stance Centre ahead of time to save wasting time and money
afterwards.

1. TECHNICAL CHARACTERISTICS

1.a Technical Data
Nominal power usage (Pn)
Nominal Thermal range (Qn)
Minimal power usage (Pm)
Minimal Thermal range (Qm)
GAS TYPE
P.C.I. (15° C 1013 mbar)
WI
(15° C 1013 mbar)
Nominal feed pressure
Consumption
Burner Pressure
Ø pilot flame nozzle
Ø main burner nozzle
nozzles
Ø gas connection
Maximum flue gas load
flue gas temperature
Category
WATER
Input range
Water temperature elevation
Minimum pressure
Nominal pressure
Maximum pressure
Ø Water connections
Ø flue gas release tube
DIMENSIONS AND WEIGHTS
Height
Length
Depth
Weight
Note: relative cold water temperature of 15 °C
kW
19,0
21,8
7,5
9,0
METHANE GAS
G20
MJ/m3
34,02
MJ/m3
45,67
mbar
20
m3/h
2,31
kg/h
-
mbar
12,20
mm
0,28
mm
1,18
N.
g/s
13,20
°C
185
select. min.
l /min
da 2,5 a 5
°C
approximately 50
bar
bar
bar
mm
DEVICE
mm
592
mm
314
mm
245
Kg
10,60
When using the device the following safety rules must be applied:
Do not use the machine for purposes other than those inten-
ded by the manufacturer.
Do not block the intake and dissipation grills or the ventilation
openings in the area where the device is installed with rags,
paper or any other materials.
If a gas leak is detected, do not switch on any electrical de-
vices, telephones or any other objects that could produce a
spark. Ventilate the area by opening the doors and windows
and switch off the gas supply.
Do not place objects on top of the device.
Do not leave flammable containers or substances in the area
where the device is installed.
Do not attempt to repair the machine if it breaks down and/or
works incorrectly.
Children or inexperienced persons are prohibited from using
the device.
It is prohibited to open sealed elements.
To maintain the proper functioning of the device:
- Periodically clean the devices exterior with soapy water, this im-
proves its appearance as well as preserving it from corrosion in
the long term.
- Do not use solvents, powders or abrasive sponges.
- Do not clean the device and/or its parts with flammable materials
(e.g. petrol, alcohol, diesel etc.).
The water heater package contains:
2
Two knobs to attach to the control panel after installation
1
Water filter to insert in the water valve pipe fitting.
Baxi 11p
kcal/h
16.340
18.748
6.424
7.740
LIQUID GAS
G30
G31
116,09
88
80,58
70,69
28-30
37
-
-
1,72
1,69
27,50
35,10
0,16
0,71
11
1/2"
12,40
13,00
180
182
II2H3+
Baxi 11p
select. max
da 5 a 10,8
approximately 25
0,2
2
10
1/2"
110
PACKAGE
655
367
280
12,60
4
Baxi 14p
kW
23,7
27,2
7,5
9,0
METHANE GAS
LIQUID GAS
G20
G30
34,02
116,09
45,67
80,58
20
28-30
2,88
-
-
2,14
13,00
27,00
0,28
1,18
13
1/2"
18,40
17,70
168
163
Baxi 14p
select. min.
da 2,5 a 6,7
approximately 50
approximately 25
0,2
2
10
1/2"
130
DEVICE
650
363
245
12,10
kcal/h
20.374
23.392
6.424
7.740
G31
88
70,69
37
-
2,11
34,30
0,16
0,72
19,00
158
select. max
da 6,7 a 13,6
PACKAGE
713
416
280
14,50

Advertisement

Table of Contents
loading

This manual is also suitable for:

14p

Table of Contents