- Remove the screws (C)
- Shift the casing upwards to free it from the upper and lateral ho-
oks
- Shift the casing forwards
- To reinsert the casing, follow the above steps in reverse order
4.b Troubleshooting: problems and solutions
For the best functioning of the water heater, to prolong its lifetime
and ensure that it is always safe, ensure that it is inspected at least
once a year by a trained professional. The trained professional is
to perform the following maintenance operations:
- Remove any rust from the burner
- Remove any deposit on the glow plug by the electrode
- Clean the combustion tank
- Check the ignition, switching off and general functionality of the
device
- Check that the gas and water tubes and connections are sealed
Warning: the flowing repair instructions are only to be performed by
qualified and authorized technicians.
PROBLEM
There is no spark
The pilot does not switch on when
there is a spark
The burner does not switch off
when the water turns off
The exchanger blade becomes
dirty in a small amount of time
There is a smell of gas
There is a smell of gas
CAUSE
-
Exhausted battery
-
Electrical cable of device is disconnected
-
Electrical card is broken
-
There isn't sufficient water pressure
-
The membrane is broken
-
The electrode is damaged
-
Safety device broken
-
No gas supply
-
Air in the gas tubes
-
Grime on the gas shutter
-
Valve piston or stem is locked in open po-
sition
-
Micro lever is locked in open position
-
If an LPG supply, check the gas pressure
-
Poor draught or dusty surroundings
-
Yellow flame
-
Excess gas consumption
-
Due to the loss of gas in the tubes, check
the tubes and find the leak
-
It can be caused by obstruction in the flue
gas circuit
-
Excess gas consumption
A
Fig. 16
-
Substitute
-
Insert
-
Test, substitute
-
Repair the device to guarantee pressure,
rotate the selector knob all the way to the
right
-
Substitute
-
Substitute
-
Substitute
-
Open the gas tap
-
Release gas
-
Test, clean
-
Disassemble, clean and eventually substi-
tute
-
Test
-
Regulate and if necessary substitute the
tank pressure regulator
-
Check the smoke channel efficiency
-
Check the gas type and clean the burner
-
Check and regulate
-
Do not activate electric switches or any
object that produces sparks in local area
-
Check the efficiency of the smoke channel
and the flue gas conduit
-
Check and regulate