Installation
Figure 1.
9.
10. The gas valve is now open for refrigerant flow. If refrigerant lines are longer than fifteen feet

Outdoor condensation drainage (Heat pump type only)

When the unit is heating, the condensing water and defrosting water can be drained out reliably
through the drain hose.
Installation:
Install the outdoor drain elbow in a 25mm hole on the base plate, and joint the drain hose to the
elbow, so that the wastewater formed in the outdoor unit can be drained out to a proper place.
14
Vacuum Pump and Leak inspection
The gas valve can now be opened. Open the gas valve by removing the shut-off valve cap
and turning the valve stem 1/4 turn counterclockwise using 1/4" Open End or Adjustable
wrench.
(8 m), it will be necessary to adjust system refrigerant charge upon completion of installation.
MXW-SVN15A-EN