Honeywell TrueZONE HZ432K/U Installation Manual page 6

Table of Contents

Advertisement

Installation Guide
WIRING
5
Connect DATS as shown.
Connect outdoor air temperature sensor as shown.
6
Required for dual fuel systems; optional for other
multistage systems. If using the C7089R1013 wireless
outdoor sensor and THM4000R wireless adapter on
2- to 4-zone systems, see page 11.
Connect equipment as shown here
7
or on pages 5–9.
HVAC
24 VOLT TRANS.
C
R
W
W2
FAN RELAY
G
Y2
Y
COMPRESSOR
RELAY
When a wireless thermostat, Portable Comfort Control, wire-
less outdoor air temperature sensor, or other RedLINK™ wireless
8
device is used on systems up to four zones, wire the THM4000
Wireless Adapter Module to the ABCD terminals on the zone panel.
For systems with more than 4 zones, see page 11.
CAUTION: Do not wire the A-B-C-D terminals of the THM5320R Wireless Equipment Interface Module
to the A-B-C-D terminals on the HZ322 zone control panel. Doing so will damage the components.
9
Connect a dedicated transformer as shown.
69-2198—03
C7735A1000
RH
RC
W1/E
W2
W3
Y1
Y2
G
O
B
DS/BK
M24809
Fig. 9
DATS
DATS
M24804
Fig. 7
C7089U1006
OUTDOOR
TEMPERATURE
SENSOR
For oil heat with a separate transformer for cooling,
remove this jumper.
For other systems, leave jumper in place and wire to
HVAC R terminal with 18 gauge solid copper wire.
The DS/BK terminal is used with a variable-speed fan.
If the HVAC equipment has DS, BK, ODD, or DHUM ter-
minals, wire that terminal to the DS/BK terminal. When
greater than 25% of zones are calling for cooling, this
terminal will be energized and the fan will operate at nor-
mal speed. When 1 zone or fewer than 25% of zones are
calling for cooling, the terminal will be de-energized and
the fan will run at a reduced rate, which will reduce the
amount of air that needs to be bypassed. This reduces
blower speed on most variable speed blowers. Refer to
HVAC equipment manufacturer instructions.
L1
R
(HOT)
L2
C
DEDICATED
TRANSFORMER
4
OT
OT
M28207
Fig. 8
THM4000R
POWER
WIRELESS SETUP
CONNECTED
CONNECT
WIRELESS
ADAPTER
Fig. 10
R
C
M24806
Fig. 11
A
B
C
D
M28193