New Or Replacement Line Set - Haier GE NS23AM Service Manual

High efficiency air conditioner system up to 23 seer (22 seer2)
Table of Contents

Advertisement

Location
Service box
Top of unit*
Between units
Against wall
NOTE: At least one side should be unobstructed by a wall or
other barrier.
Table 2. Clearances
6"*
Figure 9.
DO LOCATE THE UNIT:
With proper clearances on sides and top of unit
On a solid, level foundation or pad (unit must be level
to within ± 1/4 in./ft. per compressor manufacturer
To minimize refrigerant line lengths
DO NOT LOCATE THE UNIT:
On brick, concrete blocks or unstable surfaces
Near clothes dryer exhaust vents
Near sleeping area or near windows
Under eaves where water, snow or ice can fall directly
on the unit
With clearance less than 2 ft. from a second unit
With clearance less than 4 ft. on top of unit
Minimum Clearance
30"
48"
24"
6"
24"
30" around
Control
Box
Page 12

New or Replacement Line Set

IMPORTANT
If this unit is being matched with an approved line set
or indoor unit coil that was previously charged with
mineral oil, or if it is being matched with a coil which
was manufactured before January of 1999, the coil and
empty all existing traps. Polyvinyl ether (PVE) and polyol
ester (POE) oils are used in GE Appliances variable-
capacity units charged with HFC-410A refrigerant.
Residual mineral oil can act as an insulator, preventing
proper heat transfer. It can also clog the expansion
device and reduce system performance and capacity.
and the detailed Installation and Service Procedures
manual will void the warranty.
Flush the existing line set per the following instructions.
For more information, refer to the Installation Instruction.
line sets or indoor coil when the system contains
contaminants (i.e., compressor burn out).
Polyvinyl ether (PVE) oil is used in the NS23A24M, 36M,
and 48M with rotary compressors. For installations of the
NS23A24M, 36M, and 48M units with refrigerant lines or
coils previously charged with R410A and POE oil, GE
with R410A refrigerant to remove excess POE oil that may
be in the system. The NS23A60M air conditioners have
variable capacity scroll compressors that use POE oil.
NS23A60M units with refrigerant lines or coils previously
to remove the POE oil.
If a new line set is being installed, size the piping per Table 3.
Model
Liquid Line
24
3/8
36
3/8
48
3/8
60
3/8
* Fittings should be supplied by the installer.
to 1-1/8" adapter.
Table 3.
NOTE: Special consideration must be taken for line sets
over 50 feet. See Refrigerant Piping Guidelines.
23 SEER
Suction Line
3/4
7/8
7/8
1-1/8
31-5000746 Rev. 0