Preparation
PREPARE THE OPENING
The Advantium 240V can be installed in
combination with other GE/Monogram appliances.
Always follow each product's Installation
Instructions to complete the installation.
Single Advantium 240V Installation:
Order a 30" wide single oven cabinet or cut the
opening in a wall to the dimensions shown.
30"
23-1/2"
25-1/4"
17-1/2"
36-3/4"
Min.
the floor to the cutout in any single or combined
installation.
7/8" overlap on the bottom of the opening for
all models. Allow 1-1/4" case trim overlap on the
top for models PSB9120 and 3/4" overlap on the
top for models ZSC2200, ZSC2200, ZSC2201 and
ZSC2202.
of the opening.
When installed over a single oven or a warming
drawer, allow at least 2" between the two openings.
This separation will provide clearance for bottom
overlap of the Advantium 240V and the other
appliance overlaps.
Construct a solid oven floor of 3/8" min. thick plywood
supported by 2 x 4 or 2 x 2 runners on all sides.
flush with the bottom edge of the cutout.
Installation Preparation
WITHOUT
an Accessory Storage Drawer
PREPARE THE OPENING
Installation over a GE/Monogram
Warming Drawer:
Construct
Base
Min. 3/8"
Plywood
Supported
by 2x4 or
2x2 Runners
NOTE: Additional clearances between the cutouts
all Four
may be required. Check to be sure the oven supports
Sides
above the Warming Drawer location do not obstruct
the required interior depth and height. See Warming
Drawer installation instructions for details.
6
23-1/2"
30"
25-1/4"
17-1/2"
36-3/4"
Min.
(CONT.)
Construct
Solid Bottom
Min. 3/8"
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
2" Min.
(3" recommended)
Per warming
drawer
requirement