【 Sewing counter 】
UP counter
Every time the sewing of one shape is performed,
the existing value is counted up. When the existing
value is equal to the set value, the count-up screen
is displayed.
DOWN counter
Every time the sewing of one shape is performed,
the existing value is counted down.
When the existing value is reached to "0", the
count-up screen is displayed.
【 No. of pcs. Counter 】
UP counter
Every time one combination sewing is performed, the existing value is counted up. When the
existing value is equal to the set value, the count-up screen is displayed.
DOWN counter
Every time one combination sewing is performed, the existing value is counted down. When the
existing value is reached to "0", the count-up screen is displayed.
35