Skyflow SSMF
Installation and Maintenance Instructions
THESE INSTRUCTIONS MUST BE READ FULLY BEFORE
COMMENCING INSTALLATION
Code
SSMF315/6-5-2
SSMF315/4-5-2
SSMF350/6-5-2
SSMF350/4-4-2
SSMF400/6-5-2
SSMF400/4-5-2
SSMF450/6-5-2
SSMF450/4-4-2
SSMF500/6-5-2
SSMF560/6-3-2
Code
SSMF315/6-5-3
SSMF315/4-5-3
SSMF350/6-5-3
SSMF350/4-5-3
SSMF400/6-5-3
SSMF400/4-5-3
SSMF450/6-5-3
SSMF450/4-4-3
SSMF500/6-5-3
SSMF500/4-4-3
SSMF560/6-3-3
SSMF560/4-2-3
SSMF560/4-4-3
SSMF630/6-3-3
Code
A
B
SSMF31
710
684
SSMF35
800
784
SSMF40
800
784
Supply
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
Supply
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
400V/3Ph/50Hz
C
D
E
325
85
610
240
445
90
730
250
445
90
730
250
FL Amps
Output kW
1.05
0.12
1.80
0.25
1.05
0.12
1.80
0.25
1.05
0.12
3.60
0.55
6.00
0.55
4.90
0.75
6.00
0.55
6.00
0.55
FL Amps
Output kW
0.68
0.18
1.40
0.37
0.68
0.18
1.40
0.37
0.68
0.18
2.00
0.75
0.94
0.25
2.00
0.75
2.00
0.55
4.30
2.00
0.55
4.30
6.78
5.36
F
G
H
J
636
250
750
756
300
870
756
300
870
r/min
935
1395
885
1300
820
1330
935
1290
890
875
r/min
955
1415
920
1330
855
1460
910
1380
920
1.5
1390
910
1.5
1390
3.0
1435
2.2
965
K
L
M
Wght
500
460
610
600
550
700
600
550
700
kg
20
25
27

Advertisement

loading

Summary of Contents for Elta Skyflow SSMF

  • Page 1 Skyflow SSMF Installation and Maintenance Instructions THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION Code Supply FL Amps Output kW r/min SSMF315/6-5-2 230V/1Ph/50Hz 1.05 0.12 SSMF315/4-5-2 230V/1Ph/50Hz 1.80 0.25 1395 SSMF350/6-5-2 230V/1Ph/50Hz 1.05 0.12 SSMF350/4-4-2 230V/1Ph/50Hz 1.80 0.25 1300...
  • Page 2 All electrical installation must be carried out by suitably qualified and competent personnel in accordance with all current statutory requirements. These instructions cover only the Elta Fans Ltd product and do not include the supply or installation of any safety equipment that may be required e.g. adequate guarding or protection from rotating parts and proper electrical isolation.
  • Page 3: Installation

    Upon receipt, the fan equipment should be visually inspected to check for any damage. Ensure that the impeller is free to rotate. If there are any queries concerning the fan equipment, Elta Fans Ltd should be contacted prior to the installation.
  • Page 4: Fan Maintenance

    START-UP Before power is supplied to the unit, check that the wiring is correct as per the fan connection diagram. At initial start-up, check that impeller rotation and airflow direction is correct. Check that the motor amperage draw does not exceed the nameplate rating. FAN MAINTENANCE Inspection of the fan at least once every 12 months is recommended to ensure that the motor, fan blades, and supporting guards, are clean.
  • Page 6 GUARANTEE Elta Fans Ltd will, free of charge, within a period of 1 year from the date of despatch from their works, repair or at its option replace any goods which are proved to have defects as a result of defective materials or workmanship.

This manual is also suitable for:

Skyflow ssmf315/6-5-2Skyflow ssmf315/4-5-2Skyflow ssmf350/6-5-2Skyflow ssmf350/4-4-2Skyflow ssmf400/6-5-2Skyflow ssmf400/4-5-2 ... Show all