PUMP
Bellows
Pump
Hose
Remaining
Hose
HEATER
1 Disassembly Top Plate, Control Panel
Assembly, Drawer Panel Assembly,
Cabinet Cover Assembly, Lower Cover
Assembly.
Remove pump outlet hose.
2
Circulation
Hose
Remove tub pump bellows.
3
4
Remove cap(Remaining Hose).
5
Disconnect the wiring.
Three screws are unscrewed from the cabinet.
6
Remove the pump to arrow direction.
7
• Rating : 220/240V 50Hz
• Resistant : 162~176Ω
1 Loosen the nut.
2 Remove washing heater by pulling out.
< Heater for Washing>
• Rating : 230V 2000W
• Resistant : 24.5~28.5Ω
CAUTION
When assembling the washing heater, insert
the heater to heater clip on the bottom of tub
and check the position of wire color.
62