INLET VALVE
DOOR
1 Disconnect the wiring connector.
2 Remove the valve by two screws of the valve
holder.
※
When reconnecting the connector
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
1 Open the door completely.
2 Remove the three screws from the hinge.
※
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
Removing method of remained water
Pull it out from hose.
※
First, prepare a bucket to put in the remained
water.
CAP(REMAING HOSE)
58