Electrical Requirements - Gas Dryer - Maytag MLG24PDAGW Installation Instructions Manual

Commercial gas dryer
Hide thumbs Also See for MLG24PDAGW:
Table of Contents

Advertisement

Available languages

Available languages

Recessed Area Installation Instructions
This dryer may be installed in a recessed area.
This dryer must not be installed in a closet with a door.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes and
ordinances.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
recess as the dryer.
Minimum Installation Clearances
Back
Sides
Recessed
51 mm
0 mm
(2")
51 mm (2")
305 mm
(12")
0 mm (0")
Recessed
side view
Additional clearances for wall, door, and floor moldings may be
required or if external exhaust elbow is used.
Product Dimensions
Top dryer
exhaust
Top dryer
gas line
235 mm
Gas
(9
")
1
4
460 mm
1054 mm
(18
")
(41
/
")
1
1
8
2
940 mm
(37")
140 mm
(5
")
1
2
NOTE: Gas lines
Bottom
located 32 mm
dryer
(1
") inward
1
4
gas line
from adjacent
side.
Top
Front
305 mm
(0")
(12")
0 mm
(0")
Recessed
front view
Electric
1054 mm
(41
")
1
2
83 mm
(3
Bottom
Back View
dryer
exhaust
Product Dimensions (cont.)
127 mm (5")
Door
0 mm
(0")
Electrical Requirements – Gas Dryer
343 mm
(13
")
1
2
Important: Observe all governing codes and ordinances.
You will need an earthed electrical outlet located within 610 mm
(2 feet) of either side of the dryer.
This dryer is supplied/fitted with an electricity supply cord and
plug. It should be connected to electricity supply socket at the
voltage shown on the rating plate. The minimum supply fuse
capacity should be 12A. The dryer must be positioned so that the
plug is clearly visible and accessible. This plug also provides the
function of an emergency stop control for the user. If the fitted
plug is not used, the electrical connection must be carried out
by a competent electrician in accordance with local or national
codes.
If the supply cord is damaged, it must be replaced with a
")
1
4
specially terminated cord by an authorized service agent or
a similarly competent person in order to avoid a hazard.
Do not use an adapter.
Do not use an extension cord.
737 mm (29")
686 mm (27")
603 mm
(23
")
3
4
Side View
1940 mm
(76
")
3
8
approx. 25 mm
(1")
5