Air King AIF10X Operating Manual

Air king inline exhaust fan instructions-operating manual
Hide thumbs Also See for AIF10X:

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS -
Models: AIK14X, AIK16X, AIK24Y, AIK26Y,
AIF4X, AIF6Y, AIF8X, AIF10X,
AIG4, AIG6
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
WARNING:
DO NOT CONNECT POWER SUPPLY UNTIL FAN
IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
TO THE FAN IS LOCKED IN OFF POSITION.
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
5S7635036 New 9-06
OPERATING MANUAL

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
9. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
10. Suitable for use with solid-state speed control.
11. This unit has rotating parts and safety precautions should be
exercised during installation, operation and maintenance.
12. Guards must be installed when fan is within reach of personnel
or within seven (7) feet of working level or when deemed
advisable for safety.
13. NEVER place a switch where it can be reached from a tub or
shower.
14. Do not insert or allow fingers or foreign objects to enter the
motor.
WARNING:
www.airkinglimited.com
In-Line Exhaust Fan
DO NOT USE IN KITCHENS
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Air King AIF10X

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AIK14X, AIK16X, AIK24Y, AIK26Y, AIF4X, AIF6Y, AIF8X, AIF10X, AIG4, AIG6 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing for Fan Installation 1. When selecting fan mounting location, the following criteria should be considered: a) Mounting to minimize noise generated by fan operation: Mounting the fan as far as possible from the intake point will minimize fan operating noise from being transmitted back through the duct work.
  • Page 3 Joist/Stud Screws Collar/Damper Figure 4 2. Once the wall/ceiling material is in place, install the grill into the collar by pushing it firmly inward towards the collar until it fits flush against the wall/ceiling material (Figure 5). Collar/Damper Figure 5 SECTION 5 Existing Construction 1.
  • Page 4 NOTE: When using insulated flex duct, it is recommended that the inner vinyl core be screw clamped or taped to the inlet and outlet and that the vapor barrier surrounding the insulation be taped to the fan housing. NOTE: When attaching flex duct to the collar/damper combination and an immediate elbow is necessary, be certain that the elbow is installed with a "soft"...
  • Page 5: Troubleshooting Guide

    Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you.
  • Page 6: Replacement Parts Diagram

    Motor - AIF6X Motor - AIF8X Motor - AIF10X Cover Plate - AIF4X Cover Plate - AIF6X Cover Plate - AIF8X, AIF10X Screw - AIF4X Screw - AIF6X, AIF8X, AIF10X Mounting Bracket - AIF4X, AIF6X Mounting Bracket - AIF8X, AIF10X...
  • Page 7 INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Modèles: AIK14X, AIK16X, AIK24Y, AIK26Y, AIF4X, AIF6Y, AIF8X, AIF10X, AIG4, AIG6 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 INSTRUCTIONS D’INSTALLATION AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation en prévision de l’installation du ventilateur 1. Lorsque vous choisissez l’emplacement pour l’installation du ventilateur, les critères suivants doivent être pris en compte : a) Installation visant à...
  • Page 9 Montant / Solive Collet / clapet Matériel du mur/plafond Figure 4 2. Une fois le matériel du mur/plafond en place, installez la grille dans le collet en la poussant fermement vers le collet jusqu’à ce qu’elle soit à effleurement du matériau du mur/plafond (Figure 5).
  • Page 10 REMARQUE : Lorsqu’un conduit isolé flexible est utilisé, il est recommandé de fixer l’âme de vinyle interne du trou d’entrée et de sortie à l’aide d’une vis de serrage ou de ruban adhésif et que le pare-vapeur entourant le revêtement isolant soit fixé à l’aide de ruban adhésif au châssis du ventilateur.
  • Page 11: Guide De Dépannage

    3c. Ventilateur endommagé au cours de l’expédition. Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 12 Moteur - AIF8X Moteur - AIF10X Plaque de finition - AIF4X Plaque de finition - AIF6X Plaque de finition - AIF8X, AIF10X Vis - AIF4X Vis - AIF6X, AIF8X, AIF10X Support de montage - AIF4X, AIF6X Support de montage - AIF8X, AIF10X Passe-câble...

Table of Contents