HDD LED

The HDD (IDE Hard Disk Drive) LED
connection is located on pins 13 and
14 of JF1. Attach the IDE hard drive
LED cable to display disk activity.
Refer to the table on the right for pin
defi nitions.

NIC1 LED

The NIC1 (Network Interface Control-
ler) LED connection is located on pins
11 and 12 of JF1. Attach the NIC1
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.

NIC2 LED

The NIC2 (Network Interface Control-
ler) LED connection is located on pins
9 and 10 of JF1. Attach the NIC2
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.
Overheat/Fan Fail/Power
Fail/UID LED
Connect an LED to pins 7 and 8 of
JF1 to provide advanced warning of
chassis overheating, a fan failure or
a power supply failure. These pins
also work with the front UID indicator,
which will activate as either a solid
or fl ashing blue LED depending on
whether the LED was activated via
IPMI or the UID button. Refer to the
tables on the right for pin defi nitions
and status indicators.
Chapter 5: Advanced Serverboard Setup
HDD LED
Pin Defi nitions (JF1)
Pin#
13
14
* Pin 13 is for UID button (when used with UID
panel) or for 3.3V power for HDD LED (when
used with non-UID panel)
NIC1 LED
Pin Defi nitions (JF1)
Pin#
11
12
NIC2 LED
Pin Defi nitions (JF1)
Pin#
9
10
OH/Fan Fail/Power Fail LED
Pin Defi nitions (JF1)
Pin#
Defi nition
7
UID LED Signal
8
OH/Fan Fail/Pwr Fail Signal
Red LED Indications
State
Solid
Blinking (1/4 Hz)
Blinking (1 Hz)
Blue LED Indications
State
Solid
Blinking
5-13
Defi nition
See below*
HDD Active
Defi nition
Vcc
NIC1 Active
Defi nition
Vcc
NIC2 Active
Indication
Overheat
Power Fail
Fan Fail
Indication
UID (via Button)
UID (via IPMI)