Install The Hood (Standard Installation) - Broan EPLEC130SS Installation Use And Care Manual

Table of Contents

Advertisement

N
1 ] Run house power cable between service panel and hood location. For hood with power
2 ] Hang hood from 2 rear mounting screws previously installed. Slide hood back towards wall
3 ] Secure the hood to the cabinet using 2 no. 8 x 5/8" round head wood screws (included in parts
20

Install the Hood (Standard Installation)

OTE:
Two installers are recommended because of the weight of this hood.
cable access located on back of hood, run the house power cable into the hood through
the strain relief previously installed in step 9 on page 11. For hood with power cable access
located on top, tighten the strain relief to the power cable before inserting the strain relief in
the knockout hole.
until mounting screw heads are engaged in narrow end of keyhole slots in top of hood.
Tighten screws securely and maintain a hold on the hood until completing step 3.
bag). Insert 1 screw per side, in the slots (as shown below). Attach power cable to the hood
using the strain relief.
Screw previously
tighten in step 2.
4 ] Connect ductwork to hood and use metal foil duct tape to make joints secure and airtight.
Make sure that the damper assembly (or round duct plate) enters the ductwork and that
the damper opens and closes freely.
BACK OF HOOD
DUCTED INSTALLATION ONLY