NEC Express5800/R120g Maintenance Manual page 198

Express server
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
9040
PEI_CPU_SELF_TEST_FAILED
Detected CPU Error on CPU #1 An error was detected on CPU
9041
Detected CPU Error on CPU #2 An error was detected on CPU
9042
9060
PEI_CPU_MISMATCH
9080
Link in Slow Speed Made
between CPU1 and CPU2.
9081
Link Failure between CPU1
and CPU2
9082
Link width Error between
CPU1 and CPU2
9E80
Forced to use CPU with
error.
A001
Memory Error detected in
CPU1_DIMM1
A002
Memory Error detected in
CPU1_DIMM2
A003
Memory Error detected in
CPU1_DIMM3
A004
Memory Error detected in
CPU1_DIMM4
A005
Memory Error detected in
CPU1_DIMM5
A006
Memory Error detected in
CPU1_DIMM6
A007
Memory Error detected in
CPU1_DIMM7
A008
Memory Error detected in
CPU1_DIMM8
A00D
Memory Error detected in
CPU2_DIMM1
A00E
Memory Error detected in
CPU2_DIMM2
A00F
Memory Error detected in
CPU2_DIMM3
A010
Memory Error detected in
CPU2_DIMM4
A011
Memory Error detected in
CPU2_DIMM5
A012
Memory Error detected in
CPU2_DIMM6
A013
Memory Error detected in
CPU2_DIMM7
A014
Memory Error detected in
CPU2_DIMM8
Online Spare Memory was not
A420
ready.
Mirroring Memory was not
A421
ready.
Lockstep was not ready.
A423
198
Cause
An error was detected in CPU
initialization.
#1.
#2.
CPU #1 and #2 are not the
same type.
Low-speed mode was detected
on bus between CPU1 and
CPU2.
Connection failure was detected
on bus between CPU1 and
CPU2.
Connection decline was detected
on bus width between CPU1 and
CPU2.
An error was detected in CPU,
but the CPU was forcedly
enabled.
An error was detected in
CPU1_DIMM1.
An error was detected in
CPU1_DIMM2.
An error was detected in
CPU1_DIMM3.
An error was detected in
CPU1_DIMM4.
An error was detected in
CPU1_DIMM5.
An error was detected in
CPU1_DIMM6.
An error was detected in
CPU1_DIMM7.
An error was detected in
CPU1_DIMM8.
An error was detected in
CPU2_DIMM1.
An error was detected in
CPU2_DIMM2.
An error was detected in
CPU2_DIMM3.
An error was detected in
CPU2_DIMM4.
An error was detected in
CPU2_DIMM5.
An error was detected in
CPU2_DIMM6.
An error was detected in
CPU2_DIMM7.
An error was detected in
CPU2_DIMM8.
Memory Sparing feature is
disabled in this memory
configuration.
Memory Mirroring feature is
disabled in this memory
configuration.
Memory LockStep feature is
disabled in this memory
configuration.
Express5800/R120g-2E, T120g Maintenance Guide
Solution
Contact your sales representative.
Confirm the setting for Memory RAS Mode in
SETUP. If Memory Sparing, Memory Mirroring, or
Memory LockStep feature is enabled and DIMM
is degraded, this POST error is displayed.
Run SETUP, change parameter for Memory
Retest to Yes, and then execute Save Changes
and Exit.
If the same error persists, contact your sales
representative.
1. POST Error Message