Page 1
Extractor hood LI60LBC24 User manual and installation instructions Register your product on My Siemens and discover exclusive ser- vices and offers. siemens-home.bsh-group.com/welcome The future moving in. Siemens Home Appliances...
en Safety Table of contents 1.3 Restriction on user group This appliance may be used by children aged INFORMATION FOR USE 8 or over and by people who have reduced physical, sensory or mental abilities or inad- Safety .............. 2 equate experience and/or knowledge, Avoiding material damage........
Safety en ▶ Clean the grease filters regularly. WARNING ‒ Risk of poisoning! ▶ Never work with naked flames close to the Risk of poisoning from flue gases being appliance (e.g. flambéing). drawn back in. Room-air-dependent heat-pro- ▶ Do not install the appliance near a solid ducing appliances (e.g.
en Avoiding material damage The light emitted by LED lights is very WARNING ‒ Risk of explosion! dazzling, and can damage the eyes (risk Highly caustic alkaline or highly acidic clean- group 1). ing agents in conjunction with aluminium parts ▶ Do not look directly into the switched-on in the interior of the appliance may cause ex- LED lights for longer than 100 seconds.
Environmental protection and saving energy en 3 Environmental protection and saving energy 3.1 Disposing of packaging Clean or replace the filters at regular intervals. ¡ The effectiveness of the filter is retained. The packaging materials are environmentally compat- ible and can be recycled. Put the cooking lid on.
en Familiarising yourself with your appliance 5 Familiarising yourself with your appliance 5.1 Controls Activating or deactivating ventilation Lighting The controls are used to configure all functions of your appliance and to obtain information about the operat- ing status. 6 Basic operation 6.1 Switching on the appliance 6.3 Switching on the lighting Pull out the filter pull-out.
Cleaning and servicing en 7.5 Cleaning grease filters manually WARNING ‒ Risk of burns! The appliance will become hot during operation. The grease filters filter the grease from the cooking va- Allow the appliance to cool down before cleaning it. ▶ pour. Regularly cleaned grease filters guarantee a high level of grease removal.
en Troubleshooting 8 Troubleshooting You can rectify minor faults on your appliance yourself. WARNING ‒ Risk of electric shock! Read the troubleshooting information before contacting Incorrect repairs are dangerous. after-sales service. This will avoid unnecessary costs. Repairs to the appliance should only be carried out ▶...
Installation instructions en Depending on the model, the rating plate can be found: 10.1 Product number (E-Nr.) and production ¡ Inside the appliance (remove grease filters for ac- number (FD) cess). You can find the product number (E-Nr.) and the pro- ¡ On top of the appliance. duction number (FD) on the appliance's rating plate.
Page 10
en Installation instructions room-air-dependent heat-producing appli- WARNING ‒ Risk of fire! ance is being operated. Grease deposits in the grease filter may catch ▶ It is only possible to safely operate the ap- fire. pliance if the pressure in the room in which ▶...
Page 11
Installation instructions en Incorrect repairs are dangerous. 11.7 Instructions for the electrical ▶ Repairs to the appliance should only be connection carried out by trained specialist staff. In order to safely connect the appliance to the elec- ▶ Only use genuine spare parts when repair- trical system, follow these instructions.
Page 12
en Installation instructions Screw the mounting brackets to the unit. In doing 11.10 Installation so, only tighten the screws tight enough that the Checking the unit mounting bracket can still be moved. Screw the appliance onto the mounting brackets. Check whether the fitted unit is level and has suffi- Align the appliance and the mounting brackets in cient load-bearing capacity.
Page 13
Installation instructions en Open the backflow flap and remove the reducing Insert the reducing disc and close the backflow flap. disc . Ensure that the guide groove is in the correct posi- tion when refitting the reducing disc. Measuring the airflow In order to measure the pressure drop, attach the ▶...
Page 14
en Installation instructions 11.11 Air flow diagrams You can find the air flow diagrams below. Forced ventilation – adjustment diagram Static pressure drop Cut-away rings Existing opening of the reducing disc Without reducing disc Air flow = The A-measured sound pressure level at 10 m² sabin = The A-measured sound pressure level relative to 1 pW K-factor q=k*√Δp...
Page 15
Installation instructions en Basic ventilation – adjustment diagram Static pressure drop Setting Air flow = The A-measured sound pressure level at 10 m² sabin = The A-measured sound pressure level relative to 1 pW Measuring range 10–20 l/s Average values K-factor 0.46 0.57 0.70 0.80...
Page 16
BSH Hausgeräte GmbH Carl-Wery-Straße 34 81739 München, GERMANY siemens-home.bsh-group.com Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG *9001578323* 9001578323 (021117)