Venting Installation - Superior Fireplaces WRE3036WH Installation & Operation Instructions

Residential and outdoor wood-burning fireplace
Table of Contents

Advertisement

12
/
" Ref.
1
4
6"
Ref.
33°
3" Nom.
1
/
" Max.
1
12" Min.
2
9" Min.
Fireplace Opening
OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)
The installation of an outside air kit should be
performed during the rough framing of the fire-
place due to the nature of it's location. Outside
combustion air is accessed through a vented
crawl space (AK4F) or through a sidewall (AK4).
See Figure 22 on page 16 for instruction of
operating air kit.
CAUTION: Combustion air
inlet ducts shall not terminate
in attic space.
The maximum height for the
air vent can not exceed 3 feet
below the flue gas outlet of the
termination.
6
FIREPLACE INSTALLATION
Combustible
Material
Safe
Zone for
Projection of
Combustible
Materials
Upper
Section of
Fireplace
Figure 4 - Mantel Clearances to Combustible Material

VENTING INSTALLATION

www.SuperiorFireplaces.US.com
Continued
Top View of Fireplace
8.0"
33°
SAFE ZONE
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Figure 5 - Outside Air Kit
FIREBOX
3.0"
Combustible
Min. to
Material Must
Perpendicular
Not Overlap
Side Wall
Front Face
12"
Air Inlet
Location
Must Allow
For Bushes
or Snow
Air Inlet
Eyebrow
Vent Hood
Required for
Wall Installation
2" Max.
127020-01A