Fireplace Operation - Toshiba HAORI RAS-B10E2KVRG-A Owner's Manual

Table of Contents

Advertisement

9.5 FIREPLACE OPERATION

Keep indoor unit's fan blowing continuously during thermo off, to circulate
heat from other sources over the room. There are three setting parameters:
Default setting > Fireplace 1 > Fireplace 2
Fireplace 1:
● During thermo off period, the indoor unit's fan will continue to run by the
same speed, previously selected by end-user.
Fireplace 2:
● During thermo off period, the indoor unit's fan will continue to run at
super-low speed, programmed from factory.
Fireplace Operation Setting
1. Press MENU button for enter menu setting and press TEMP. button to
select FIREPLACE
2. Enter FIREPLACE set by press MENU button.
triangle mark will stop blink and setting feature will be blink instead.
3. Select FIREPLACE operation by press TEMP. button.
FIREPLACE 1
FIREPLACE 2
4. Confirm selected feature by press MENU button again.
When feature had selected will return to menu selection display triangle mark
will blink
5. Leave from menu setting display by select EXIT.
Note:
● While Fireplace operation on heating mode, indoor unit fan always runs and
cold air breezing might be occurred.
● Fireplace will operate in Heating mode only.
Blink both triangle and
feature mark Feature not
yet set
None
Blink only triangle Feature
already set
9.6 TIMER OFF OPERATION
To set the timer OFF when the air conditioner is operating.
1. Press MENU button for enter menu setting and press TEMP. button to
select TIMER OFF.
2. Enter TIMER set by press MENU button.
triangle mark will stop blink and setting feature will be blink instead.
3. Select TIMER OFF by press TEMP. button.
Can select TIMER OFF from 0.5 - 12hrs.
4. Confirm TIMER OFF by press MENU button.
5. Leave from menu setting display by select EXIT.
Note:
● The setting will be saved for the next same operation.
Cancel TIMER OFF
6. During TIMER OFF already set (no.5) press MENU button and press
TEMP. button to select TIMER OFF.
7. Press MENU button again will cancel TIMER OFF.
8. Leave from menu setting display by select EXIT.
Blink both triangle and
feature mark Feature not
yet set
Blink only triangle
Feature already set
Blink only triangle
Feature already set
Blink both triangle and feature
mark Feature not yet set

Advertisement

Table of Contents
loading

Table of Contents