U-Line UHCR115-SS01B User Manual & Service Manual page 43

Hide thumbs Also See for UHCR115-SS01B:
Table of Contents

Advertisement

USER GUIDE
LIMIT SWITCH SPECIFICATIONS
• Normally closed Bi-metal switch
• Open temperature: 104°F
• Close temperature: 83°F
The function of this switch is to open in the event of an
overheating condition. This bi-metal thermostat is
normally closed and does not initiate the ice harvest
cycle. The ice harvest cycle is initiated by a double throw,
single pole temperature located remotely from the ice
maker assembly.
Troubleshooting Extended
3.00
28.12
Figure 6. Limit Switch
43
u-line.com
183-10