  • Page 1 USER GUIDE & SERVICE MANUAL Model: UHCP115-SS81A...
  • Page 2 USER GUIDE & SERVICE MANUAL Click on any section below to jump directly there Table of Contents Intro Troubleshooting Product Liability Safety Warranty Claims Safety and Warning Parts Disposal And Recycling Ordering Replacement Parts R600a Specifications Installation System Diagnosis Guide Environmental Requirements Compressor Specifications Electrical...
  • Page 3 U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4 USER GUIDE Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5 USER GUIDE Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:...
  • Page 6 USER GUIDE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
  • Page 7 USER GUIDE Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8 14 15⁄16” (379 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, FRONT 28”...
  • Page 9 USER GUIDE Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Tighten screws fully. Cutout width for a side-by-side installation is the cutout 4.
  • Page 10 Plastic may crack compression fitting. or rupture with age and cause damage to your U-Line recommends using accessory water hookup kit - home. Part # ULAWATERHOOKUP. The kit includes a 10’ (3 m) braided flexible water supply line and a brass hose fitting.
  • Page 11 USER GUIDE 3. Locate water 8. Install retaining clip. valve in the front of the unit and thread water supply line through. NOTICE Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve.
  • Page 12 Normal Proper Drain CAUTION With Trap If your U-Line unit did not come with a factory Poor Drainage, Water Will Back Up installed drain pump you must use a gravity style drain connection. For assistance in determining if your unit has a pump please contact U-Line.
  • Page 13 Air Gap (Optional Hook-Up) requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Shut-Off...
  • Page 14 USER GUIDE Anti-Tip Bracket Slide unit out so screws on top of unit are easily accessible. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
  • Page 15 USER GUIDE General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable. level.
  • Page 16 USER GUIDE Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille Disconnect power to the unit. Slightly loosen three screws on bottom hinge. Remove two grille screws.
  • Page 17 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Door Swing Wall Wall 1/4" Min. 2-1/8" Min. (6 mm) (54 mm) Door Swing Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets.
  • Page 18 USER GUIDE Door Adjustments TO REVERSE THE DOOR HINGE COVER Hinge cover included with the literature bag is optional. To install hinge cover: Press hinge cover squarely over hinge. Hinge Cover Remove arrow clips: With a putty knife or other flat tool, gently pry each arrow clip from hinge mounting holes.
  • Page 19 USER GUIDE Remove door by tilting forward and lifting door off bottom hinge. Retain shoulder washers; they will be Install gasket into channel, reused. beginning at one corner and pressing in firmly. Insert arrow clips into holes Press down on middle horizontal portion of gasket until it adheres to the door surface.
  • Page 20 USER GUIDE First Use All U-Line controls are preset at the factory. Initial startup requires no adjustments. See CONTROL OPERATION section for more details. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
  • Page 21 USER GUIDE Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn On or OFF Option Open Door Closed Door Hold press and release White White Adjust light color Press to scroll through lighting BrightShield BrightShield options...
  • Page 22 See Control Operations sections for details and other options. For more information about BrightShield™ visit www.u-line.com For more information about Vyv™ Antimicrobial Light Technology visit www.vyv.tech...
  • Page 23 USER GUIDE Your clear ice machine is preset to produce ice between the optimal dimensions illustrated below: Cube Details ICE CUBE THICKNESS AND ADJUSTMENT 1/4" TO 1/2" 1/16" TO 1/8" NOTICE (6.4 mm to 12.7 mm) (1.6 mm to 3.2 mm) DIMPLE ICE BRIDGE Ice thickness adjustment should only be made...
  • Page 24 USER GUIDE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door. Airflow and Product Loading...
  • Page 25 CLEAR ICE MACHINE CLEANING CYCLE Clean any glass surfaces with a non-chlorine glass cleaner. Your U-Line clear ice machine has an automatic clean alert function. Cleaning cycles should be run as notified. Do not use cleaners not specifically intended for...
  • Page 26 Place unit into CLEAN mode by holding for 5 U-Line Clear Ice Machine Cleaner is used to remove lime seconds. scale and other mineral deposits. Refer to the following When water begins flowing over the evaporator steps to initiate the self-cleaning cycle.
  • Page 27 USER GUIDE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary. WARNING Disconnect electric power to the unit before cleaning the condenser.
  • Page 28 USER GUIDE Extended Non-Use For questions regarding winterization, please call VACATION/HOLIDAY, PROLONGED SHUTDOWN U-Line at 414.354.0300. The following steps are recommended for periods of extended non-use: CAUTION Remove all consumable content from the unit. Damage caused by freezing temperatures is not covered by the warranty.
  • Page 29 Find a Servicer page to locate a U-Line Authorized servicer. If your product is in Troubleshooting - What to check when problems occur: warranty please make sure to register it at www.U-Line.com/u-lineregistration.
  • Page 30 The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 31 Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 32 USER GUIDE Parts UHCP115-SS81A Item Description U-Line P/N BACK PANEL 80-54863-00 BYPASS VALVE ASSEMBLY 80-55516-00 CIRCULATION PUMP 80-54137-00 COMPRESSOR ASSY, R600 80-54376-01 CONDENSER ASSEMBLY 80-54079-00 CONDENSER FAN BLADE 80-54066-00 CONDENSER FAN MOTOR 80-54138-00 COVER W/HOOK WHITE 80-54332-00 DISPLAY MODULE 80-55214-00...
  • Page 33 Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 34 Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
  • Page 35 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
  • Page 36 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
  • Page 37 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
  • Page 38 USER GUIDE System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold Slightly warm Hot to warm Cool...
  • Page 39 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Compressor Specifications DANGER OVERLOAD PROTECTOR Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing this unit.
  • Page 40 DC outputs located on the relay/power board. Included in this section is some diagnostic tips and as always, if additional help is required please contact the U-Line Corp, “Customer Care Facility” at +1.800.779.2547 for assistance. NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components.
  • Page 41 Go to component testing and turn off fill valve, level unit if needed. Low Ice Production Dirty evaporator, dirty condenser, faulty bin Clean the evaporator using U-Line cleaner, clean the condenser coil if thermistor needed, check bin thermistor reading in service mode. Ice Does Not Fall...
  • Page 42 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE MAIN CONTROL The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures before attempting to remove the board for replacement or service.
  • Page 43 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Control Operation - Service UI BUTTON LAYOUT Hidden Button -Accesses Service Menu -No LED directly above. All LEDs turn on with button activation except #7. Up Button -Increases temperature -Navigates through service menu -LED activated with button activation.
  • Page 44 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS ON/OFF Press and release Unit will immediately turn ON or OFF. Adjust ice thickness See “Ice” section Sabbath Mode See “Sabbath Mode” section Silent Mode (ice production suspended for Hold...
  • Page 45 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE SERVICE MODE GUIDE SERVICE MODE GUIDE 1. THERMISTOR 1 — BIN Service Mode Menu Item This shows the pure thermistor reading with no View thermistor #1 (no offsets) offsets taken into account.
  • Page 46 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 15. CLEAR ERROR LOG 26. SOFTWARE VERSION — MAIN BOARD To clear errors, press and hold (5 seconds) Displays software version of the main control when CLR is flashing. board.
  • Page 47 MODEL NUMBER 1. Disconnect the unit from power source. 2. Push and hold the U-Line button. 3. While still holding the U-Line button, plug the unit into the appropriate power source. 4. When the flashing digits appear (3-5 seconds), use the up and down arrow buttons to select the appropriate model number*.
  • Page 48 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Control Operation - Service 6...
  • Page 49 USER GUIDE Thermistors provide reliable temperature readings preset defrost timer during defrost cycles. The unit will u-line.com using a resistance which varies based on surrounding otherwise operate normally. Refer to defrost section. temperatures. If a faulty thermistor is suspected it may be tested using an accurate ohmmeter.
  • Page 50 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Defrost These models have no defrost options. Defrost 1...
  • Page 51 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.