Remove Fan And Cover; Convection Cooling; Evaporator Fan Replacement - U-Line HWC515IG01A User Manual & Service Manual

Table of Contents

Advertisement

USER GUIDE

Remove Fan and Cover

CONVECTION COOLING

This unit is equipped with an advanced convection cooling
system. Convection cooling stabilizes cabinet temperature,
cools product faster and increases energy efficiency.
Evaporator Fan
The evaporator fan is responsible for circulating warm air
from the refrigeration zone, past the evaporator and back
into the refrigerated zone.
The evaporator fan is factory set to have a 1 minute delay
at the beginning of a cooling cycle. This delay gives the
evaporator time to cool properly before warm air is passed
over it. The fan will continue to run for an additional 2
minutes at the end of a cooling cycle. Fan delay times can
be modified through the service menu.
Evaporator fan operation is also determined by door switch
state. If the door switch circuit opens, the fan will stop.
When the door switch circuit is closed the fan will either
continue running with the cooling cycle, or if not currently
cooling, the fan will run for 1 minute to circulate air and
clear any condensation that may have appeared on glass
doors and shelves.
Note: If the unit is set to sabbath mode, the evaporator
fan will no longer respond to the state of the door switch.
In order to operate efficiently, the evaporator fan blade
and vents should be unobstructed and free of any dust
buildup.

Evaporator Fan Replacement

Should the evaporator fan need to be replaced follow the
steps below.
1.
Remove any product from the unit.
2.
Remove unit from cabinetry to access rear.
3.
Disconnect power to the unit.
4.
Remove back panel from unit.
5.
Disconnect fan electrical connection at rear of unit.
Remove Fan and Cover
6.
Remove insulating foam from refrigerant line pass-
through hole as needed to gain clearance for fan plug.
7.
Remove internal shelving.
8.
Remove 8 evaporator cover screws.
9.
Grasp evaporator cover, pull forward and up as bottom
of cover is installed behind the front edge of the drain
trough.
10. While pulling the evaporator cover clear of the unit, it
may be necessary to use your free hand to manipulate
the fan plug end through the pass-through hole.
11. Remove the 4 screws mounting the fan shroud to the
evaporator plate.
12. Remove and replace fan. Take special care to properly
route fan wire.
57
u-line.com

Advertisement

Table of Contents
loading

Table of Contents