Smart Fan Configuration - Biostar P43D3+ Manual

Hide thumbs Also See for P43D3+:
Table of Contents

Advertisement

P43D3+ BIOS Manual

Smart Fan Configuration

Advanced
Smart Fan Configur ation
CPU S mart Fan
Smart Fan Calibrat ion
Contr ol Mode
o
Fan C trl OFF( C)
o
Fan C trl On( C)
Fan C trl Start val ue
Fan C trl Sensitive
vxx.xx (C)C opyright 198 5-200x, Amer ican Megatre nds, Inc.
CPU Smart Fan
T his item allows you to control the CPU Smart Fan function.
Options:
Disabled (default) / Auto
Smart Fan C alibration
Choose this item and then the BIOS will auto test and detect the CPU/System fan
fun ctions and show CPU/System fan speed.
Control Mode
T his item provides several operation modes of the fan.
Options:
Quiet / Performan ce / Manual
Fan Ctrl OFF(℃ )
If the CPU/System T emperature is lower than the set value, FAN will turn off.
0~127 (℃) (Interval: 1℃)
Options:
Fan Ctrl On(℃ )
CPU/System f an starts to work under smart fan function when arrive this set value.
0~127 (℃) (Interval: 1℃)
Options:
BIOS S ETUP UTILITY
[ Disabled]
13
When you choice [Auto]
plea se run the
cali bration to d efine
the Fan paramete rs for
Smar t Fan contro l
S elect Screen
S elect Item
C hange Option
+-
F1
G eneral Help
F1 0
S ave and Exit
ES C
E xit

Advertisement

Table of Contents
loading