5. Orientation control

Orientation control is a function to stop a rotating machine at the specified phase.
The following is a block diagram of orientation control.
Switched by
digital input: 116/117
θref (A672)
+
-
θfb

5.1 Initialization method for phase

• Set the initialization method for the phase in A670.
A670=0: When the phase initialization signal (input terminal function 188/189) is turned ON from OFF, the current
phase is initialized to A671.
A670=1: When the Z phase of the encoder option is input, the current phase is initialized to A671.
(Caution)
• When A675 > A676 (the gear ratio of the machine is less than 1), do not use A670=1. (The current phase cannot be
specified uniquely)
• When A670=1, input the encoder Z phase signal.
P - gain: F362
I - gain: F363
D - gain: F366
P - gain: A314
I - gain: A315
D - gain: A318
PID
Controller
±A673
Terminal OUT
118/119
±A674
Fref
Motor
Controller
+
-
Ffb
23