Toshiba RAS-B22PKVSG-TR Service Manual page 8

Table of Contents

Advertisement

2-3. Operation Characteristic Curve
<Cooling>
12
RAS-B24PKVSG-E,-TR
10
8
RAS-B22PKVSG-E,-TR
6
4
2
0
0
10
20
30
40
Compressor Speed (RPS)
2-3. Capacity Variation ratio According to Temperature.
<Cooling>
105.0
100.0
95.0
90.0
85.0
RAS-B24PKVSG-E,-TR
80.0
75.0
70.0
65.0
60.0
Capacity ratio : 100 %=
55.0
6.10kW (RAS-B22PKVSG-E,-TR)
7.00kW (RAS-B24PKVSG-E,-TR)
50.0
45.0
40.0
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Outside Temperature (
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
C/WB 24
C
o
o
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V
90
100 110
50
60
70
80
RAS-B22PKVSG-E,-TR
Conditions
o
o
Indoor : DB 27
C/WB 19
C
o
o
Outdoor : DB 35
C/WB 24
C
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V
o
C)
<Heating>
12
12
RAS-B24PKVSG-E,-TR
10
10
8
RAS-B22PKVSG-E,-TR
8
6
6
4
4
2
2
0
0
0
10
20
30
Compressor Speed (RPS)
<Heating>
120.0
100.0
80.0
60.0
40.0
Capacity ratio : 100 %=
7.00kW (RAS-B22PKVSG-E,-TR)
8.00kW (RAS-B24PKVSG-E,-TR)
20.0
0.0
-15
-10
- 8 -
FILE NO. SVM-18033
Conditions
Indoor : DB 20
C/WB 15
o
Outdoor : DB 7
o
C/WB 6
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V
40
50
60
70
80
90
100 110
Conditions
o
Indoor : DB 20
C/WB 15
Outdoor : DB 7
o
C/WB 6
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V
-5
0
5
Outside Temperature ( ºC)
C
o
o
C
o
C
o
C
10