(g) Shutdown Log enquiry
Syntax
Header
Category
Enquiry
0x83
0x30
Answer
Header
Answer
Enquiry
0x70
0x00
Return Data1: 0x00 - 0xFF
Code Table(4-c)
Shutdown Information
bit0
Reserved
bit1
1: FAN operation is abnormal
bit2
1: Backlight is abnormal
bit3
1: Temperature sensor is abnormal
bit4
1: Main power supply is abnormal
bit5
1: Digital power supply is abnormal (3.3 V, 5 V) 0: Normal
bit6
1: Analog supply is abnormal (5 V/9 V)
bit7
1: Scaler is abnormal
Code Table(4-d)
[a]Function
0x00
Model Name
0x01
Serial Number
0x02
Operation Time
0x03
Soft Version(Main)
0x07
Digital 3.3 V
0x09
Digital 5 V
0x0A
Temp1
0x0D
Temp(P/S)
0x0F
Soft Version(Scaler)
0x10
Analog5 V/9 V
0x11
Shutdown Log
0x12
Digital 3.3 V(Failure)
0x13
Digital 5 V(Failure)
0x14
Analog5 V/9 V(Failure) 0x00 - 0xFF
*
0x20
Busy to INPUT
* Busy to INPUT should be judged by Busy
16
Function
Data1
0x11
0xFF
Return to Data Size
Return Data1
0x02
Code Table(4-c)
0: Normal
0: Normal
0: Normal
0: Normal
0: Normal
0: Normal
[b]Range/Switch code
0x08 - 0x09
0x001E8480 - 0x002DC6BF
(2,000,000 - 2,999,999)
0x00000000 - 0xD693A3FF
(0sec._3,599,999,999sec.)
0x0000 - 0xFFFF
0x00 - 0xFF
0x00 - 0xFF
0x00 - 0xFF
0x00 - 0xFF
0x0000 - 0xFFFF
0x00 - 0xFF
0x00 - 0xFF
0x00 - 0xFF
0x00 - 0xFF
0x00 Non Busy
0x01 Busy
Non Busy. Busy to INPUT may be incorrectly judged during start when it is judged by only Non Busy.
Data2
Check Sum
0xFF
0xC0
Check Sum
0xXX
Command
Control
Enquiry
No
Yes
Yes
Yes
No
Yes
Completed
Standby Power On
Enable
Enable
Enable
Enable
Enable
Enable
FWD-42LX1