- Wait five (5) minutes to allow possible
accumulated gas to clear.
- Set the IFT-ECM 3-position selector switch to ON
or REMOTE position. Module will beep once and
flash a three GREEN LED code on successful
startup.
- If placed in ON position, the appliance will ignite
normally if the error condition was corrected.
- If placed in REMOTE position, use the paired IFT-
RC400, IFT-RC150 or wired wall switch to start
the appliance; appliance will ignite normally if the
error condition was corrected.
- If the IFT-ECM re-enters the lock-out condition
after these steps, call your dealer for service.
Reset Switch Operation
CAUTION! Risk of burns! Appliance surfaces are hot
when operating and during cool down. Use care and
wear gloves when opening the front and accessing com-
ponents inside the appliance.
The control module (IFT-ECM) may lock out under certain
conditions. When this occurs, the appliance will not ignite
or respond to commands and is shut down. If the IFT-
ECM is in the LOCK-OUT mode, it will be necessary to
reset the control module.
For natural gas applications, the IFT-ECM has a soft
lockout. This means the appliance will have to be restarted
using the FLAME function on the remote control.
For propane applications, the appliance has a hard
lockout and the IFT-ECM must be reset. This appliance
has a reset switch located inside the control cavity for
propane applilcaitons. See Figure 3.8 for approximate
location.
To reset the IFT-ECM Control Module:
• Be aware the appliance may be HOT, use
care in accessing the reset switch.
Turn the appliance off at a wall switch location if so
equipped.
Wait five minutes to allow possible accumulated gas to
clear.
For Propane Applications Only:
Remove decorative barrier front from appliance.
Locate reset switch inside the appliance. See Figure
3.8.
Hold reset switch down for one second and release. A
"beep" will signal module is reset.
Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Owner Manual • 2619-984 Rev. N • 11/22
Appliances with Wall Switch and Remote
• Turn wall switch back to "ON" position.
main menu on remote control and restart fireplace.
The fireplace will start as it would under normal
circumstances.
Appliances with Wall Switch Only:
• Turn wall switch back to "ON" position. The fireplace
will ignite as it would under normal circumstances.
Appliances with Remote Only:
• Turn fireplace back on using the main menu on the
remote control. The fireplace will ignite as it would
under normal circumstances.
• Reinstall decorative barrier front on appliance.
• If the IFT-ECM re-enters the LOCK-OUT condition
after this procedure, contact your dealer for service.
RESET SWITCH - PROPANE ONLY
RESET SWITCH - PROPANE ONLY
Figure 3.8 Reset Switch Location
Appliance ON/OFF:
A wall control, thermostat or remote control may be used
to control the ON/OFF function of the appliance. Follow
instructions included with the installed control.
Optional LED's
• LED's are an option on RAVE42-IFT-B, RAVE36-IFT-B
and RAVE32-IFT-B appliances.
• The optional LED's must be used in conjunction with
the IFT-RC400 remote control. The intensity of the
these lights is controlled through the RC400 remote
control.
Optional Fan Kit
If desired, a fan kit may be added. The Passive Heat Kit
is not compatible with a fan on the RAVE-B models.
Contact your dealer to order the correct fan kit.
Go to
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rave32-ift-bRave36-ift-b

Table of Contents