Configuring The E8491B Trig In And Trig Out Ports - HP E8491B IEEE 1394 Configuration And User's Manual

Pc link to vxi
Table of Contents

Advertisement

Configuring the E8491B
Trig In and Trig Out Ports
Figure 3-1. Configuring the HP E8491B External Trigger Ports.
1. Trigger routing is only available using the HP SICL ivxitrigroute function.
44 VXI Programming Using the IEEE 1394 Serial Bus
Asserting Triggers - HP SICL
ivxitrigoff
ivxitrigon
ixtrig
I_TRIG_ALL
I_TRIG_TTL0 to I_TRIG_TTL7
I_TRIG_ECL0 to I_TRIG_ECL1
I_TRIG_EXT0 (specifies faceplate 'Trig Out' port)
Routing Triggers- HP SICL
ivxigettrigroute
1
ivxitrigroute
I_TRIG_ALL
I_TRIG_TTL0 to I_TRIG_TTL7
I_TRIG_ECL0 to I_TRIG_ECL1
I_TRIG_EXT0 (specifies faceplate 'Trig Out' and 'Trig In' ports)
Configuration of the E8491B external 'Trig In' and 'Trig Out' ports is done
through the HP I/O Libraries' 'I/O Config' utility. This portion of the utility
is shown in the following figure.
When 'External Trig In' is selected, the faceplate 'Trig In' port is configured
for the trigger level and state (normally high or normally low) selected.
When 'External Trig Out' is selected, the faceplate 'Trig Out' port is
configured for the state (normally high or normally low) selected.