LG 27HK510S-W.AWP Owner's Manual page 44

Medical monitor
Table of Contents

Advertisement

18. [Response Time] (Command: m g)
ʢ Controls the Response Time.
Transmission (m)(g)( )(Set ID)( )(Data)(Cr)
Data
00: [Faster]
02: [Normal]
Ack (g)( )(Set ID)( )(OK/NG)(Data)(x)
19. [Black Stabilizer] (Command: m h)
ʢ Controls the Black Sharpness Optimization function.
Transmission (m)(h)( )(Set ID)( )(Data)(Cr)
Data
Min: 00 - Max: 64
Ack (h)( )(Set ID)( )(OK/NG)(Data)(x)
20. [Uniformity] (Command: m i)
ʢ Controls the Uniformity function.
Transmission (m)(i)( )(Set ID)( )(Data)(Cr)
Data
00: [On]
Ack (i)( )(Set ID)( )(OK/NG)(Data)(x)
44
01: [Fast]
03: [Off]
01: [Off]
21. [Gamma] (Command: m j)
ʢ Adjusts the Gamma settings.
Transmission (m)(j)( )(Set ID)( )(Data)(Cr)
Data
00: [Gamma 1.8]
02: [Gamma 2.2]
04: [Gamma 2.6]
Ack (j)( )(Set ID)( )(OK/NG)(Data)(x)
22. [Color Temp] (Command: k u)
ʢ Adjusts the color Temp.
Transmission (k)(u)( )(Set ID)( )(Data)(Cr)
Data
00: [Custom]
02: [7500K]
04: [Manual]
Ack (u)( )(Set ID)( )(OK/NG)(Data)(x)
23. [Red] (Command: j w)
ʢ Adjusts the red.
Transmission (j)(w)( )(Set ID)( )(Data)(Cr)
Data
Min: 00 - Max: 64
Ack (w)( )(Set ID)( )(OK/NG)(Data)(x)
01: [Gamma 2.0]
03: [Gamma 2.4]
05: [DICOM Gamma Curve]
01: [6500K]
03: [9300K]

Advertisement