Electrolux EWF 12040 User Manual page 23

Table of Contents

Advertisement

132980570_EN.qxd
30/06/2006
P0038
Cleaning the pump
The pump should be inspected if
• the machine does not empty and/or
spin
• the machine makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump.
Proceed as follows:
• Disconnect the appliance.
• If necessary wait until the water has
cooled down.
• Open the pump door.
P1114
• Place a containfer close to the pump
to collect any spillage.
• Pull out the emergency emptying
hose, place it in the container and
remove its cap.
• When no more water comes out,
unscrew the pump cover and remove
it. Always keep a rag nearby to dry up
spillage of water when removing the
cover.
15:12
Pagina
23
P1115
• Remove any objects from the pump
impeller by rotating it.
• Put the cap back on the emergency
emptying hose and place the latter
back in its seat.
P1117
• Screw the pump cover fully in.
• Close the pump door.
Warning!
When the appliance is in use and
depending on the programme selected
there can be hot water in the pump.
Get other manuals https://www.bkmanuals.com