Wire the ACU

10
Follow the steps below to wire the ACU.
a. Dress the data and power cables from the
antenna. Using wire strippers, strip back the
insulation of each wire approximately 1/4"
(6 mm) and gently twist each wire to ensure a
good electrical connection.
b. Locate the ACU terminal strip connector
supplied in the kitpack (see Figure 19).
c. Connect the data cable wires to the terminal
board connector, as shown in Figure 19. Then
using a #0 flat-head screwdriver, tighten each
terminal screw to secure the wires in place.
d. Connect the power cable wires to the
terminal strip connector, as shown in
Figure 19. Then using a #0 flat-head
screwdriver, tighten both terminal screws to
secure the wires in place.
e. Press and lock the terminal strip connector
into place on the rear of the ACU (see
Figure 20).
f. Connect one end of the ACU's 120 VAC
power cord to the rear of the ACU (see
Figure 20). Then connect the other end into a
UPS or surge protector.
g. Optional - If you plan to connect the ACU to
an onboard network using the supplied
Ethernet cable, connect it to the ACU's
Ethernet port (see Figure 21).
Figure 19 Terminal Strip Connector
Power Cable
Red (+42V)
Black (Gnd)
1
1
2
2
3
3
4
4
5
5
6
6
Wht/Gry
Gry/Wht
Wht/Org
Org/Wht
Data Cable (Body Color/Strip Color)
Figure 20 Terminal Strip/Power Supply
Terminal
Board
ANTENNA
ETHERNET
FUSE
AC INPUT
100-240V~
3.15A
160W MAX
250V~
FAST ACTING
50/60 HZ
This device complies with Part 15 of the FCC rules. Operation is subject
CAUTION
to the following two conditions: (1) This device must not cause harmful
interence, and (2) This device must accept any interference received,
RISK OF ELECTRIC SHOCK
DO NOT OPEN
including interference that may cause undesired operation.
120 VAC
Power
Cord
Figure 21 Ethernet Port
ANTENNA
ETHERNET
FUSE
AC INPUT
100-240V~
3.15A
160W MAX
250V~
FAST ACTING
50/60 HZ
This device complies with Part 15 of the FCC rules. Operation is subject
CAUTION
to the following two conditions: (1) This device must not cause harmful
RISK OF ELECTRIC SHOCK
interence, and (2) This device must accept any interference received,
DO NOT OPEN
including interference that may cause undesired operation.
ETHERNET
Terminal
Screw (x12)
7
7
8
8
9
9
10
10
11
11
12
12
Blu/Wht
Wht/Blu
Brn/Wht
Wht/Brn
RS232
Tested to comply
Wi-Fi
with FCC Standards
Meets
requirements
KVH and TracVision are registered
trademarks of KVH Industries, Inc.
RS232
Tested to comply
with FCC Standards
Wi-Fi
Meets
requirements
KVH and TracVision are registered
trademarks of KVH Industries, Inc.
13

Advertisement

Table of Contents
loading

Table of Contents