E5CC-T
Nomenclature
E5CC-T
Press O Key once to go to
Program Setting Level.
Press O Key for at least 3
seconds to go to Initial Setting
Level.
Use the M Key to change to another parameter.
Press M and D Keys simultaneously for at
least 1 second to switch between run and reset
status.
Use S Key to change the digit (default setting).
Dimensions
Controllers
E5CC-T
12
Front panel
Temperature unit
Operation indicators
(64)
4
60
48 × 48
1
Waterproof Packing
Mounting Adapter
(Accessory)
(Accessory)
The Setup Tool port is on the top of the Temperature Controller.
It is used to connect the Temperature Controller to the computer
to use the Setup Tool.
The E58-CIFQ2 USB-Serial Conversion Cable is required to
make the connection.
Refer to the instructions that are provided with the USB-Serial
Conversion Cable for the connection procedure.
Note: Do not leave the USB-Serial Conversion Cable
connected when you use the Temperature Controller.
No. 1 display
PV or specified monitor/setting parameter
No. 2 display
SP or specified monitor/parameter value
Top-panel Setup Tool port
UD
Use the
Keys to set the
parameter.
U
Press
Key for at least 1 second
when Process value/Set point
parameter are displayed in Program
SP Mode to go to Display Segment
Selection parameter in Program
Setting Level.
Mounted Separately
48 × 48
60 min.
45
+0.6
45
0
• Recommended panel thickness is 1 to 5 mm.
• Group mounting is not possible in the vertical direction. (Maintain
the specified mounting space between Controllers.)
• To mount the Controller so that it is waterproof, insert the
waterproof packing onto the Controller.
• When two or more Controllers are mounted, make sure that the
surrounding temperature does not exceed the allowable operating
temperature specified in the specifications.
• To attach the USB-Serial Conversion Cable to the control panel,
use a panel thickness of 1 to 2.5 mm.
Top View of E5CC-T
(Unit: mm)
Panel Cutout
Group Mounted
(48 × number of units - 2.5)
45
Group mounting does not
allow waterproofing.
+0.6
0
+1.0
0
+0.6
0