BLOWER DATA
EL296DF090XV60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1115
Factory Default
1005
890
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific
1
DIP Switch Settings.
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
First Stage Heating Speed - cfm
1425
1355
1280
1215
1160
1055
1010
950
First Stage Cooling Speed - cfm
Medium-Low Medium-High
1265
1400
1150
1275
1065
1150
HEATING
Second Stage Heating Speed - cfm
COOLING
Second Stage Cooling Speed - cfm
High
Low
2
1600
1600
1450
1450
1270
1270
Page 54
1895
1825
1740
1660
1575
1455
1365
1265
Medium-Low Medium-High
1750
1970
1630
1810
1450
1645
High
2
2130
1975
1810