Summary of Contents for DUROMAX Hybrid Elite XP13000EH
Page 1
Call our Customer Care Team Toll Free 8-5 pm PST Mon-Fri information in this manual. We reserve the right to 844-DUROMAX change this product at any time without prior notice.
CONTENTS Introduction Introduction ........................6 General Safety Procedures ................... 8 Unit and Purchase Information .................. 12 Carbon Monoxide Safety ..................... 13 Generator Components Generator Components ....................16 Package Contents ......................18 Generator Setup Shipping Braces ......................21 Wheel Kit Installation ....................22 Connect the Battery ....................
Page 4
CONTENTS Maintenance and Care Maintenance Schedule ....................52 Break-In Period ......................53 Maintenance Log......................53 Checking the Oil ......................54 Changing the Oil ......................55 Cleaning the Air Filter ....................56 Spark Plug Maintenance ....................58 Emptying the Gas Tank ....................60 Cleaning the Fuel Filter Cup ..................
Page 6
DUROMAX The DuroMax Way is more than just a brand, it is our understanding and appreciation of just how important power can be to someone without it… DUROMAX FOR HOME DUROMAX FOR WORK DUROMAX FOR PLAY Electricity in our home not...
INTRODUCTION DuroMax Power Equipment is headquartered in Ontario, California and is the industry’s leader in Dual Fuel portable generator technology. In addition to a full assortment of portable generators ranging from digital inverters to large 15,000-watt portable standby units, their product line includes pressure washers, engines, pumps, and accessories.
GENERAL SAFETY PROCEDURES SAFETY ALERT SYMBOL The safety alert symbol is used with one of the safety words (DANGER, WARNING, or CAUTION) to alert you of hazards. Please pay attention to these hazard notices both in this manual and on the engine. Please familiarize yourself with the following safety symbols and words: ●...
Page 9
WARNING: This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline. ● Do not operate near an open flame. ●...
Page 10
GENERAL SAFETY PROCEDURES In addition to the above safety notices, please familiarize yourself with the safety and hazard markings on the generator. DANGER DO NOT OVERFILL 1.5” THE GAS TANK OVERFILLING CAN RESULT IN A FIRE, EXPLOSION, OR DEATH.
Page 11
CAUTION HIGH TEMPERATURE DON’T TOUCH HOT EXHAUST DANGER KEEP SAFE DISTANCE BURN RISK CARBON MONOXIDE SAFE DISTANCE DON’T TOUCH...
UNIT AND PURCHASE INFORMATION Serial Number Serial number The serial number is located on the engine block, above and to the left of the oil fill. Serial number format The serial number will be shown in two parts. The engine model, followed by the serial number.
As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, odorless threat.
Page 15
GENERATOR COMPONENTS To help you get familiar with your new DuroMax generator, please see this component section for easy reference on all the generator’s individual features.
5. Power Panel - Contains the start switch, plugs, meters, and circuit breakers. 6. Handles - Longest handles of any DuroMax model allow easy movement across any surface. 7. Battery - 12V dc battery that powers the electric start system. (Behind cover plate) 8.
PACKAGE CONTENTS Your generator comes with the items listed below. Please check to see that all of the following items are included with your generator. Double-Sided Spanner Spark Plug Wrench Screw Driver Phillips and slot blade Assorted wrenches used in Used in spark plug screwdriver used for generator generator maintenance and...
GENERATOR SETUP Step 1 - Remove Shipping Braces Unpack Remove the generator from the box. Place the largest piece of packing foam on a flat surface. Flip the generator upside down on the pad. CAUTION: NEVER attempt this if you have put fuel or oil in the generator.
GENERATOR SETUP (CONTINUED) Step 2 - Wheel Kit Installation (Optional) Install support legs Secure the support legs to the frame with the provided lock nuts. Install wheel axles Place the smallest washer onto the wheel axle bolts. Insert wheel axle bolts through the frame and secure with the provided nut and wrenches.
Page 23
Install outside wheel washers Place the other large washers onto the axles. Install cotter pins Place the cotter pin through the hole at the end of the axle and bend it out to secure the wheel. Install handles Attach the handles to the brackets on the frame using the provided bolts and nuts.
GENERATOR SETUP (CONTINUED) Step 3 - Connect the Battery Remove the battery cover Remove the battery cover plate using the wrench from the toolkit. Locate the negative cable Locate the negative battery cable above and behind the battery. One side is connected to ground and the other end needs to be connected to the battery.
Step 4 - Adding Oil The generator requires engine oil to operate properly. The generator, when new from the package, contains no oil in the crankcase . You must add the proper amount of oil before operating the generator for the first time. This amount is equal to the oil capacity of the engine crankcase: Model Number XP13000EH Engine Oil Capacity...
GENERATOR SETUP (CONTINUED) Step 5 - Adding Gasoline (Optional) Add gasoline Make sure the generator is on a level surface. Unscrew gas cap and set aside (NOTE: the gas cap may be tight and hard to unscrew). Slowly add unleaded gasoline to the fuel tank. Be careful not to overfill.
Step 6 - Grounding the Generator Attach grounding wire Ground the generator by tightening the grounding nut against a grounding wire. Connect the other end to a copper or brass grounding rod that’s driven into the earth. A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire.
STARTING THE GENERATOR If this is not your first time using the generator there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP”...
BEFORE YOU START YOUR GENERATOR Step 1 - Check the Oil Check the oil The generator is equipped with an automatic shutoff to protect it from damage due to low oil. Nonetheless, you should check the oil level of the engine before each use to ensure that the engine crankcase has a sufficient amount.
Step 2 - Check the Gas Level (Optional) Check fuel level If running the engine on gasoline check to see that there is sufficient gasoline in the fuel tank. The fuel gauge on top of the tank will give a rough estimate of the gasoline level. The gauge will appear white then fill red as the tank is filled.
STARTING THE GENERATOR Starting the Generator Using Gasoline Turn breaker OFF The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator. Turn fuel switch to GAS The fuel switch is located on the left front panel.
Page 33
Turn gas valve ON The gas valve is located above the recoil start on the bottom of the fuel tank. Rotate the valve counter-clockwise to the vertical position to turn on the gas supply. Start the generator The push button start left side of the main power panel. Press the button for 1 second and release to start the generator.
STARTING THE GENERATOR (CONTINUED) Starting the Generator Using Propane Turn breaker OFF The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator. Turn fuel switch to PROPANE The fuel switch is located on the left-hand front panel.
Page 35
Turn battery switch ON The battery switch is located on the top center of the main power panel. Turn the switch “ON” to allow power to the push-button start. Turn idle control OFF The idle control is located on the top center of the main power panel.
Page 36
STARTING THE GENERATOR (CONTINUED) Starting the Generator Using Propane WARNING: WHEN USING THE GENERATOR WITH LPG, MAKE SURE THERE IS NO POSSIBLE IGNITION SOURCE CLOSE TO THE GENERATOR. 1. Before using, make sure all of the LPG connectors and hoses are well connected and sealed.
STARTING THE GENERATOR (CONTINUED) Starting the Generator Using the Recoil Start Turn breaker OFF The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator. Select your fuel If using gasoline, see step 2 on pg.
Page 39
Close choke The choke lever is located above the air filter to the left of the recoil start. Slide the lever to the left to cut the air supply and allow more gas into the engine to start. Pull the recoil start The recoil start is located on the left side panel next to the air filter.
USING THE GENERATOR If this is not your first time using the generator there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP”...
USING THE GENERATOR AC Usage ● You may connect electrical devices running on AC current according to their wattage requirements. ● The chart below shows the rated and surge wattage of your generator according to its model number. ● The rated wattage corresponds to the maximum wattage the generator can output on a continuous basis.
Page 43
Tool or Appliance Rated (Running) Watts Additional Surge Watts Electric water heater (40 gal) 4000 Hot plate 2500 Radial arm saw 2000 2000 Electric stove 1500 Circular saw 1500 1500 Air compressor (1 HP) 1500 3000 Window air conditioner 1200 1800 Miter saw 1200...
Connecting the Generator to a Home Extension cords ● The most straightforward and affordable option. ● Zero commitment, no installation needed: Simply plug in your appliances and go! ● Perfect for renters, RV/camping trips, and power on the job-site. Transfer switch ●...
USING THE GENERATOR (CONTINUED) Connecting a Load to the Generator NOTE: Be sure to attach devices to the correct receptacle (outlet). 120V devices can be directly connected to the 120V ONLY receptacles. ● ● 120V devices can be connected to the 120/240V receptacle using an appropriate adapter. ●...
*Gauge based on twisted copper wire From home back up to just running your electric edger and everything in-between DuroMax has the power cord for you. All DuroMax cords are 100% twisted copper wire for maximum life and reliability. 120V 15A...
USING THE GENERATOR (CONTINUED) Using the Digital Multimeter When the generator is started, the display will read the current voltage. Press the MODE button to cycle through the multimeter functions. Voltage The voltage currently produced by the generator in volts. Frequency The frequency currently produced by the generator in Hz.
Hours total The number of hours the generator has been run in total. Idle Control Usage Idle control The idle control feature lowers the RPM of the generator when there is no load to save gas and decrease engine noise. When a load is applied, the engine will resume normal speed to provide usable power.
USING THE GENERATOR (CONTINUED) DC Usage CAUTION: The DC receptacle is for 12 Volt automotive-type appliances only. Do not connect any other device to this receptacle. Start the generator The push button start left side of the main power panel. Press the button for 1 second and release to start the generator.
MAINTENANCE AND CARE Proper maintenance and storage of your generator is essential to ensure trouble free use of your generator when you need it. By following the maintenance and care requirements, you can keep your generator running smooth and efficient for years to come.
MAINTENANCE AND CARE Proper routine maintenance of your generator is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING: Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously injured or killed. Always follow the inspection, maintenance recommendations, and schedules in this instruction manual.
Break-In Period As the best practice for any new combustion motor it’s recommended to perform the break in procedure as follows: ● Run the generator for the first 6-8 hours on conventional oil, then change the oil. After the break-in period synthetic oil may be used. ●...
MAINTENANCE AND CARE (CONTINUED) Checking the Oil Check the oil The generator is equipped with an automatic shutoff to protect it from damage due to low oil; nonetheless, you should check the oil level of the engine before each use to ensure that the engine crankcase has a sufficient amount.
Changing the Oil CAUTION: Worn out or dirty oil does not cool the generator properly and can lead to catastrophic engine damage. In addition to regular oil changes, it is necessary to drain the oil from the crankcase if it has become contaminated with water or dirt.
MAINTENANCE AND CARE (CONTINUED) Cleaning the Air Filter Routine maintenance of the air cleaner helps maintain proper airflow to the carburetor. Check that the air cleaner is free of excessive dirt after every use. CAUTION: Improper maintenance may cause less air to enter the engine or dirty air to enter the engine causing overheating and engine wear.
Page 57
Wash cleaner element Wash the sponge-like elements in household dish detergent and warm water. Dry cleaner element Pat dry on a dry cloth and allow the elements to dry completely. Add engine oil to elements Soak the dry elements in a small amount of engine oil. Ring out any excess oil.
MAINTENANCE AND CARE (CONTINUED) Spark Plug Maintenance The spark plug is important for proper engine operation. SPARK PLUG A good spark plug should be intact, free of deposits, and CONSULT MANUAL properly gapped. BEFORE REMOVING CAUTION: Improper maintenance may cause reduced fuel economy, misfires, trouble starting, or damage to the spark plug threads.
Page 59
Measure plug gap Measure the plug gap with a gauge. The gap should be 0.7-0.8 mm (0.028-0.031 in). Clean and re-gap If you are re-using the spark plug, use a wire brush to clean any dirt from around the spark plug base and then re-gap the spark plug.
MAINTENANCE AND CARE (CONTINUED) Emptying the Gas Tank If you have been using gasoline in your generator, before storing your generator for extended periods of time you should drain your generator fuel tank of gasoline. CAUTION: Do not store fuel from one season to another.
Page 61
Drain gas from the generator With a funnel underneath the fuel valve to catch the gas, turn the fuel valve to the “ON” position. Drain all the gas from the generator. Shut fuel valve OFF Turn the fuel valve to the “OFF” position. Replace fuel filter cup Reinstall the fuel filter cup.
MAINTENANCE AND CARE (CONTINUED) Cleaning the Fuel Filter Cup Shut fuel valve OFF Turn the fuel valve to the “OFF” position. Remove fuel filter cup Unscrew the fuel filter cup from the fuel valve using a wrench. Clean filter cup Clean the cup of all sediment using a rag or brush.
Transporting the Generator Empty the gas tank Fully drain your gas tank as shown in “Emptying the Gas Tank” on page 60-61. Disconnect the spark plug Pull on spark plug cap to disconnect spark plug from ignition wire. CAUTION: Do not obstruct any ventilation openings and keep the generator in a cool dry area.
MAINTENANCE AND CARE (CONTINUED) Storing the Generator for Same Day Use Turn the main breaker OFF Move the main breaker to the “OFF” position. Run the generator Allow the generator to run for 3-5 minutes. Turn the generator off Hold the start button for 3 seconds to shut off the generator. Turn battery switch OFF/ Store Turn the battery switch to the “OFF”...
Storing the Generator for Use Within 30 Days Turn breaker OFF and run Follow steps 1 and 2 as shown on “Storing the Generator For Same Day Use” on page 64. Shut fuel valve OFF and run dry Shut the fuel valve “OFF” and allow generator to run until it stalls out.
MAINTENANCE AND CARE (CONTINUED) Storing the Generator for Longer Than 30 Days Turn breaker OFF and run Follow steps 1 and 2 as shown on “Storing the Generator For Same Day Use” on page 64. Shut fuel valve OFF and run dry Shut the fuel valve “OFF”...
Page 67
Drain the carburetor Remove drain bolt from carburetor and drain small amount of fuel in carburetor bowl. Remove spark plug Remove spark plug as shown in “Spark Plug Maintenance” on page 58. Add oil to cylinder Add 2 tablespoons of 10W-30 motor oil directly into the spark plug hole, and pull the recoil to lubricate cylinder.
SPECIFICATIONS Model Number XP13000EH AC Rated Wattage (Gasoline) 10,500 W AC Rated Wattage (Propane) 9,975 W AC Surge Wattage (Gasoline) 13,000 W AC Surge Wattage (Propane) 12,350 W AC Rated Voltage 120/240V Dimensions 29”L x 30”W x 26”H Weight 246 lbs Recommended Oil 10W-30 Engine Displacement...
TROUBLESHOOTING Problem Problem Description Description Solution Solution Engine switch is “Off” Engine switch is “Off” Set engine switch to “On” Set engine switch to “On” Fuel valve is “Closed” Fuel valve is “Closed” Turn the fuel valve to “Open” Turn the fuel valve to “Open” Choke is open Choke is open Close the choke...
Changing/ Inspecting the Carbon Brushes The carbon brushes in conjunction with the AVR regulates power from the generator. The carbon brushes are wearable parts and should be inspected every 250 running hours. Remove generator cover Remove the 2 bolts of the generator cover then pull the cover off the generator.
Page 72
TROUBLESHOOTING (CONTINUED) Changing/ Inspecting the Carbon Brushes (Cont.) Install new brush Install new carbon brush with bolt. Connect AVR wires Insert and connect the 2 wires from the AVR, be sure to connect + and – correctly. Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts.
Changing / Inspecting the AVR Changing/ Inspecting the AVR The carbon brushes in conjunction with the AVR regulates power from the generator. If the generator is overheated or overloaded, the AVR may be damaged and require replacement. Remove generator cover Remove the 2 bolts of the generator cover then pull the cover off the generator.
Page 74
TROUBLESHOOTING (CONTINUED) Changing/ Inspecting the AVR (Continued) Disconnect wires from brush Remove the 2 wires from the AVR on the carbon brush. Install new AVR Install the new AVR with the 2 bolts. Reconnect wires to brush Insert and connect the 2 wires from the AVR, be sure to connect + and –...
Page 75
Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts.
OEM parts. Warranty Limitations DuroMax Power Equipment does not claim or hold any obligation to loss of time, freight charges, use of product, or any incidental damages from the use of this product. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED.
Page 79
As the small off-road engine owner, you should be aware that the DuroMax Power Equipment may deny you warranty coverage if your small off-road engine or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifications.
Page 80
The use of any non-exempted add-on or modified parts will be grounds for disallowing a warranty claim made in accordance with this Article. DuroMax Power Equipment will not be liable under this Article to warrant failures of warranted parts caused by the use of an add-on or modified part.
Page 81
17. Canister Mounting Brackets 18. Carburetor Purge Port Connector * Note: As they relate to the evaporative emission control system. DuroMax Power Equipment will furnish with each new engine written instructions for the maintenance and use of the engine by the owner...
CUSTOMER SERVICE Duromax Power Equipment is committed to ensuring that our products perform when they need to. Our generators are your lifeline in the event of an emergency. Should you have any problems, please contact our customer service department: DUROMAX POWER EQUIPMENT...
Page 84
5800 Ontario Mills Parkway Ontario, CA 91764 United States 844-DUROMAX REV: XP13000EH-06172022...