General Information; Performances - Drolet FOX Owner's Manual

Hide thumbs Also See for FOX:
Table of Contents

Advertisement

2. General Information

2.1

Performances

Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model
Combustion type
Fuel Type
Recommended heating area (sq. ft.
Overall firebox volume
EPA loading volume
1
Maximum burn time
Maximum heat output (dry cordwood)
Overall heat output rate (min. to max.)
Average overall efficiency
(Dry cordwood)
7
Optimum efficiency
Optimum heat transfer efficiency
Average particulate emissions rate
11
Average CO
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The overall firebox calculation is an approximation and is not intended to be used for loading. This volume includes a buffer zone to allow an easier
fuel insertion, prevent ash spillage and allow the air wash to work properly.
3
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging
from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish.
The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
4
As measured per CSA B415.1-10 stack loss method.
5
Higher Heating Value of the fuel.
6
Lower Heating Value of the fuel.
7
Optimum overall efficiency at a specific burn rate (LHV).
8
The optimum heat transfer efficiency is for the low burn rate and represents the appliance's ability to convert the energy contained in the wood logs
into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9
This appliance is officially tested and certified by an independent agency.
10
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA
th
on February 28
, 2018.
11
Carbon monoxide.
Page 6
.
)
1
2
3
2 4
3
8
9
Escape 1200 (DB03182)
Non-catalytic
Dry Cordwood
250 to 1,200 ft
2
(23 to 111 m
1.8 ft
3
(0.0510 m
3
)
1.55 ft
3
(0.0439 m
3
)
5 hours
45,000 BTU/h (13.2 kW)
12,124 BTU/h to 26,700 BTU/h
(3.55 kW to 7.83 kW)
5
74 % (HHV)
80 %
79 %
1.8 g/h (EPA / CSA B415.1-10)
74 g/h
Installation and Operation Manual - Fox et Spark II
2
)
6
79 % (LVH)
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spark iiDb03401Db03186

Table of Contents