Troubleshooting

DANGER
Risk of electric shock.
 Prior to all work on the appliance, switch off
the appliance and pull the power plug.
Appliance is not running
 Push the lever of the trigger gun, the device
will switch on.
 Check whether the voltage indicated on the
type plate corresponds to the voltage of the
mains supply.
 Check the mains connection cable for dam-
ages.
Pressure does not build up in the appliance
 Completely open the water tap.
 Appliance ventilation: Switch the appliance
on with the high-pressure hose detached
and operate (max. 2 minutes) until the water
exits the high-pressure connection without
bubbles. Switch off appliance and reconnect
high-pressure hose.
 Pull out the sieve in the water connection us-
ing flat-nose pliers and clean under running
water.
Strong pressure fluctuations
 Clean high-pressure nozzle: Remove dirt
and debris from the nozzle bore, using a
needle and rinse through with water from the
front.
 Check water flow quantity.
Appliance is leaking
 Slight leakage from the appliance pump is
normal. If the leakage increases contact the
authorized customer service.

Warranty

The warranty terms published by the relevant
sales company are applicable in each country.
We will repair potential failures of your appliance
within the warranty period free of charge, provid-
ed that such failure is caused by faulty material
or defects in manufacturing. In the event of a
warranty claim please contact your dealer or the
nearest authorized Customer Service center.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch

Technical specifications

Electrical connection
Voltage
Power consumption
Protection class
Protective class
Water connection
Max. feed pressure
Max. feed temperature
Min. feed volume
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Max. flow rate
Recoil force of trigger gun
Dimensions and weights
Length
Width
Height
Weight, ready to operate with
accessories
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Sound power level L
WA
Uncertainty K
WA
Subject to technical changes.
220-240
V
1~50-60
Hz
6 A
IPX5
II
1,2 MPa
40 °C
6 l/min
7,4
MPa
74
bar
11,0
MPa
110
bar
5,2 I/min
6 I/min
11 N
280 mm
182 mm
390 mm
4,5 kg
1,6
m/s
0,6
m/s
78
dB(A)
pA
3
dB(A)
+
93 dB(A)