Alignment Instruction
Auto white balance adjustment
The set should be working for over 30 minutes before white balance adjustment so that it can be
in a stable state. Connect CA210 to USB port of a compute with a data line, connect VG848 and
TV to COM port or virtual COM port of a computer respectively (default connection is that VG848
to COM5 and TV to COM1; enter into administrator window with password "xoceco" to change
the default connection if necessary and then save it); be sure to output VG848 signal to AV2、
YPbPr2、VGA、HDMI3 ports of TV.
Open file "White_Balance.exe", load config file "AdjustConfig.txt", then connect CA210、VG848、
TV respectively according to the indication of interface prompt .(note: set probe as "0-CAL"before
connecting to CA210, then press item "connect to CA210", set probe as "MEAS" when a prompt
"CA-210 connection and correction are normal" is displayed on the left-bottom side; default
channel for CA210 is CH02 BBY; enter into administrator window with password "xoceco" to
change the default setting if apparatus is different and then save it.)
Press item "auto white balance adjustment", auto-adjustment will be completed when a prompt
"adjusting successfully" is displayed.
Performance checkout
TV function
Input central signal to RF port, first enter menu "CHANNELS", then auto-search channels to
check if there is any omitted channel; check if output of speakers is normal; check if picture is
normal, especially make sure that the channels have been found must include ATSC and NTSC
signals.
AV/S-Video interface
Input signal to AV/S port respectively, check if picture and sound are normal.
YPbPr/YCbC port
Input YUV signal with format listed as Table2 respectively from VG848 signal generator,
check if picture and sound are normal.