Change the drain hose position
Rear view for left piping installation
Drain hose
Drain cap
How to pull the piping and drain hose out, in case of the
embedded piping.
Apply putty or
caulking material
to seal the wall
opening.
PVC tube for
drain hose (VP-20)
PVC tube for drain
hose
12.2.4
Connect the Cable to the Indoor Unit
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front
grille.
1
Install the indoor unit on the installing holder that mounted on the wall.
2
Open the front panel and grille door by loosening the screw.
3
Cable connection to the power supply through Isolating Devices (Disconnecting means).
Connect the approved polychloroprene sheathed Power supply cord 3 x 1.5 mm
o
2
2.5 mm
(2.0HP), type designation 60245 IEC 57 or heavier cord to the terminal board, and connect the
other end of the cable to Isolating Devices (Disconnecting means).
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or
o
otherwise) is too short.
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
o
conditioner shall be done socket and plug rated 15/16 A (3/4 ~ 1.75HP) or 16 A (2.0HP). Wiring work to
both socket and plug must follow to national wiring standard.
4
Bind all the Power supply cord lead wire with tape and route the power supply cord via the left side
escapement.
5
Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x
2
1.5 mm
(3/4 ~ 1.75HP) or 4 x 2.5 mm
6
Bind all the indoor and outdoor Connection cable with tape and route the connection cable via the right side
escapement.
7
Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
PIPE
HOLE
CENTER
115mm TO
HOLE CENTER
Drain hose
Connection cable
Adjust the piping
slightly downwards.
Connection cable
Piping
Drain hose
from main unit
PVC tube (VP-65) for piping
and connection cable
PVC tube for drain hose (VP-30)
Cable
Piping
Indoor unit
55 mm
2
(2.0HP) flexible cord, type designation 60245 IEC 57 or heavier cord.
Tape
Power
supply
cord
Piping
Sleeve for piping hole
Drain hose
In case of left piping how to insert the connection cable
and drain hose.
Drain hose
Piping
(For the right piping, follow the same procedure)
Tape
Connection cable
62
Connection cable
More than 950 mm
Cable
2
(3/4 ~ 1.75HP) or 3 x