Carrier PAD4 E Series Installation Instructions Manual page 36

14 seer single--packaged air conditioner system with r--410a refrigerant single phase 2--5 nominal tons (sizes 24-60) three phase 3-5 tons (sizes 36-60)
Table of Contents

Advertisement

R- -410A refrigerant operates at 50- -70 percent higher pressures than R- -22. Be sure that servicing equipment and replacement components
are designed to operate with R- -410A. R- -410A refrigerant cylinders are rose colored.
S R- -410A refrigerant cylinders manufactured prior to March 1, 1999, have a dip tube that allows liquid to flow out of cylinder in upright
position.
Cylinders manufactured March 1, 1999 and later DO NOT have a dip tube and MUST be positioned upside down to allow liquid to flow.
S Recovery cylinder service pressure rating must be 400 psig. DOT 4BA400 or DOT BW400.
S R- -410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose.
S Manifold sets should be minimum 700 psig high- -side and 180 psig low- -side with 550 psig low- -side retard.
S Use hoses with minimum 700 psig service pressure rating.
S Leak detectors should be designed to detect HFC refrigerant.
S R- -410A, as with other HFCs, is only compatible with POE synthetic oils.
S Vacuum pumps will not remove moisture from oil.
S Only use factory specified liquid- -line filter driers with rated working pressures no less than 600 psig.
S Do not install a suction- -line filter drier in liquid line.
S POE synthetic oils absorb moisture rapidly. Do not expose oil to atmosphere.
S POE synthetic oils may cause damage to certain plastics and roofing materials.
S Wrap all filter driers and service valves with wet cloth when brazing.
S A R- -410A liquid- -line filter drier is provided with every unit.
S Do not use an R- -22 TXV.
S Never open system to atmosphere while it is under a vacuum.
S When system must be opened for service, break vacuum with dry nitrogen and replace filter driers.
S Always replace filter drier after opening system for service.
S Do not vent R- -410A into the atmosphere.
S Observe all warnings, cautions, and bold text.
S Do not leave R- -410A suction line driers in place for more than 72 hrs.
36
AIR CONDITIONER WITH R- -410A QUICK REFERENCE GUIDE
51901180403

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pad4 b series

Table of Contents