GAS SUPPLY AND PIPING

GAS SUPPLY
WARNING
THIS FURNACE IS EQUIPPED AT
THE FACTORY FOR USE ON
NATURAL GAS ONLY.
CONVERSION TO LP GAS
REQUIRES A SPECIAL KIT IS
AVAILABLE AT THE DISTRIBUTOR.
FAILURE TO USE THE PROPER
CONVERSION KIT CAN CAUSE
FIRE, CARBON MONOXIDE
POISONING, EXPLOSION,
PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH. See the
conversion kit index supplied with
the furnace. This index identifies the
proper LP Gas Conversion Kit
required for each particular furnace.
IMPORTANT: Any additions, changes
or conversions required for the
furnace to satisfactorily meet the
application should be made by a
qualified installer, service agency or
the gas supplier, using factory-
specified or approved parts.
IMPORTANT: Connect this furnace
only to gas supplied by a commercial
utility.
IMPORTANT: U.L. or CSA
recognized fuel gas and CO
detector(s) are recommended in all
applications, and their installation
should be in accordance with the
manufacturer's recommendations
and/or local laws, rules, regulations or
customs.
GAS PIPING
Install the gas piping according to all
local codes and regulations of the
utility company.
If possible, run a separate gas supply
line directly from the meter to the
furnace. Consult the local gas
company for the location of the
manual main shut-off valve. The gas
line and manual gas stop must be
adequate in size to prevent undue
pressure drop and never smaller
than the pipe size to the gas valve
on the furnace. Refer to Table 6 for
the recommended gas pipe size. See
Figure 35 for typical gas pipe
connections.
Install a ground joint union within 3
ft. of the cabinet to easily remove the
gas valve assembly. Install a manual
gas stop valve in the gas line outside
the furnace casing. The manual gas
stop should be readily accessible to
turn the gas supply on or off. Install a
drip leg in the gas supply line as close
to the furnace as possible. Always
FIGURE 35
GAS PIPING INSTALLATION
MANUAL
GAS
STOP
TOP VIEW OF GAS LINE AND VALVE
BURNERS
4 TO 5 FEET
ABOVE
FLOOR REQ'D
BY SOME
UTILITIES.
GROMMET
(IN NORMAL
POSITION)
DRIP LEG
UNION
MANUAL
GAS
STOP
4 TO 5 FEET ABOVE
FLOOR REQ'D BY
SOME UTILITIES.
GROMMET
(IN NORMAL
POSITION)
DRIP LEG
UNION
DRIP LEG
BURNERS
MANIFOLD
IMPORTANT: DO NOT RUN A FLEXIBLE GAS CONNECTOR INSIDE THE
UNIT. Extend the 1/2" black pipe from the gas valve to the outside of the
cabinet.
UPFLOW
GROMMET
IN OPT. POSITION
GAS VALVE
DOWNFLOW
TOP VIEW OF GAS LINE AND VALVE
IN OPT. POSITION
BURNERS
IGNITOR
HORIZONTAL
MANUAL GAS STOP
UNION
GAS VALVE
NOTE: WHEN GAS LINE
IS IN OPT. POSITION,
SWAP LOCATION OF
GROMMET AND PLUG.
OPT. GAS LINE
POSITION
PLUG
(IN NORMAL
POSITION)
MANIFOLD
PRESSURE
TAP
IGNITOR
MANIFOLD
GROMMET
NOTE: WHEN GAS
LINE IS IN OPT.
POSITION, SWAP
LOCATION OF
GROMMET AND
PLUG.
GAS VALVE
PLUG
(IN NORMAL
POSITION)
MANIFOLD
PRESSURE
TAP
I328
MANIFOLD
I524
37