Standby Electricity Saving

The standby electricity saving function turns OFF power supply to the outdoor unit and sets the indoor unit
into standby electricity saving mode, thus educing the power consumption of the air conditioner.
The standby electricity saving function works on the following indoor units.
FTXS20G2V1B
FTXS25G2V1B
FTXS35G2V1B
CAUTION
The standby electricity saving function cannot be used for models other than the specified ones.
■ Procedure for turning ON standby electricity saving function
1) Check that the main power supply is turned OFF. Turn it OFF if has
not been turned OFF.
2) Remove the stop valve cover.
3) Disconnect the selective connector for standby electricity saving.
4) Turn ON the main power supply.
CAUTION
1) Before connecting or disconnecting the selective connector for standby electricity saving, make sure that the main power sup-
ply is turned OFF.
2) The selective connector for standby electricity saving is required if an indoor unit other than the above applicable ones is con-
nected.
■English
ATXS20G2V1B
ATXS25G2V1B
ATXS35G2V1B
1
2
3
Standby electricity saving
Standby electricity saving
function OFF.
function ON.
The standby electricity saving function is turned OFF
before shipping.
1
2
3
8