Samsung RF23R6 Series Service Manual page 15

Table of Contents

Advertisement

Items
Compressor
Condenser
Refrigerant
Model
Temperature Selection
THERMISTOR
(F-SENSOR) 502AT
Model
Temperature Selection
THERMISTOR
(F-SENSOR) 502AT
Model
Temperature Selection
THERMISTOR
(R-SENSOR) 502AT
First Defrost Cycle (Concurrent defrost of F and
R)
Defrost Cycle(FRE)
Defrost Cycle(REF)
Pause time
F/R Defrost-
Sensor
F/R Bimetal-thermo
Protector
F/R Thermo Fuse- Assy
Protector
Model
Starting type
-8℉(-22℃)
-2℉(-19℃)
8℉(-14℃)
29℉(-1℃)
42℉(5℃)
34℉(1℃)
38℉(3℃)
46℉(7℃)
Model
SPEC
Rated
Operating
temperature
Rated
Operating
temperature
15
PRODUCT SPECIFICATIONS
Specification
RF23R*
NF54M7151AN/E01
BLDC
Forced and Natural Convection Type
R600a
ON(℉)
-5℉(-20℃)
1℉(-17℃)
11℉(-12℃)
ON(℉)
32℉(0℃)
45℉(7℃)
ON(℉)
36℉(2℃)
40℉(4℃)
48℉(8℃)
6hr ± 10min
12~23hr
(vary according to the conditions used)
6~11hr
(vary according to the conditions used)
12 ±1min
THERMISTOR (502AT)
5.0 kΩ at 77℉(25℃)
AC 250V / 3A
Off : 140℉(60℃) / On : 104℉(40℃)
AC 250V / 10A
110(109)℃ Off

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rf23r6301 aa seriesRf23r6201 aa seriesRf23r6201 ed seriesRf23r6201 az seriesRf23r6201 bz series

Table of Contents