NM1250R
OPERATION
Water
Water enters the machine through the 3/8"
male flare at the rear of the cabinet, goes to
the water reservoir which it enters through the
float valve.
The water then goes out the bottom of the
reservoir tank to the bottom of the evaporator.
Reservoir overflow or evaporator
condensation is routed to the drain.
ADJUSTMENT OF THE
WATER LEVEL
EVAPORATOR
RESERVOIR
DRAIN
WATER LEVEL
STRAINER
WATER
INLET
DRAIN
November, 1988
Page 19