MAINTENANCE AND CLEANING
1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
ICE LEVEL SENSORS:
SLIDE TO REMOVE
CLEAN THE
LIGHT SENSORS
3. The bearing in the breaker should
also be checked at least two times
per year.
A. Check the bearing by:
switching the machine OFF
removing the ice chute cover
unscrewing the ice sweep
removing the water shed
unscrewing the breaker cover.
unscrewing the auger stud
Inspect the assembly, looking for wear.
See Removal and Replacement to replace
bearing or seals. Reverse to reassemble.
4. Check and tighten all bolts and screws.
CLEAN THE
WATER LEVEL
PROBE
///////////////////////////////////////////
CAUTION: THE TIP IS
MADE OF GLASS
//////////////////////////////////////////
Moving Parts Hazard.
Rotating parts can cause
personal injury.
Disconnect electrical
power before beginning.
FME Components
Shown, NME similar.
February 1997
Page 17
NME650 & FME800
PULL UP TO
REMOVE PROBE
RESERVOIR
ICE SWEEP
BREAKER
COVER