MAINTENANCE AND CLEANING
In some areas the water supply to the
icemaker will have a great deal of minerals in
it, and that will result in ann evaporator and
auger becoming coated with these minerals,
requiring a more frequent removal than twice
per year. If in doubt about the condition of the
evaporator and auger, the auger can be
removed so the parts can be inspected.
BREAKER
& BEARING
& AUGER
ASSEMBLY
Note: Water filters can filter out suspended
solids, but not dissolved solids. "Soft" water
may not be the complete answer. Check with
a water treatment specialist regarding water
treatment
For more information on removal and
replacement of these parts, see REMOVAL
AND REPLACEMENT.
Shut off water and electrical supply.
1. To remove the auger, remove the front and
top panels.
2. Remove 3 hex studs holding ice chute
cover to ice chute, and remove cover.
ALLEN
3. Unscrew and remove ice sweep.
SCREWS
4. Loosen band clamp under ice chute, and
remove ice chute from evaporator.
5. Remove 4 allen screws holding breaker to
evaporator.
6. Pull up to remove auger.
After the auger has been removed, allow the
auger to dry; if the auger is not bright and
shiny, it must be cleaned.
Clean the auger and evaporator as required.
DO NOT HONE THE EVAPORATOR.
7. Replace the water seal.
8. Reverse to reassemble.
December, 1988