Final Check List - Scotsman FM2400R Service Manual

Scotsman fm2400r ice machine: user guide
Table of Contents

Advertisement

FM2400R
FOR THE INSTALLER: Final Check List
1. Is the ice system installed
indoors in a location where
the air and water
temperatures are controlled,
and where they do not exceed
the design limitations?
2. Is there an electrical
service disconnect within sight
of the installed machine? Has
the voltage been checked,
and compared to nameplate
requirements?
3. Have all the plumbing
connections been made and
checked for leaks?
4. Has the machine and bin
been leveled?
5. Is there a minimum of 6"
clearance at the rear, left,
right and above the machine
for proper service access?
6. Is the water pressure a
minimum of 20 psig?
7. Has the machine been
secured to the bin?
8. Is there a water shut off
valve installed near the
machine?
9. Is the remote condenser
installed per local building
codes, and in a place where it
has adequate ventilation and
minimal solar heat gain?
10. Has all shipping material
and literature (inside the front
panel) been removed from the
units?
121 Have the remote
condenser and precharged
lines been properly installed?
12. Has the electrical
connection between the icemaker and the
condenser been made?
13. Verify that the master switches are in the
OFF postion.
REMOTE
CONDENSER
SECURED?
LEVELED?
PLUMBING?
14. Switch on the electrical power.
15. Refer to Pre-Start instructions, the next
page.
December, 1988
Page 12
ROOF
HOLES
SEALED?
POWER
SUPPLY?

Advertisement

Table of Contents
loading

Table of Contents